Clinical Trials Directory

Trials / Not Yet Recruiting

Not Yet RecruitingNCT07203716

Preparing Kids for MRI Using VR

Effect of Home-Based and Immediate Pre-Scan Virtual Reality Orientation on Motion Artifacts and Sedation Need in Pediatric MRI: A Three-Arm Randomized Controlled Trial

Status
Not Yet Recruiting
Phase
N/A
Study type
Interventional
Enrollment
150 (estimated)
Sponsor
Haseki Training and Research Hospital · Academic / Other
Sex
All
Age
5 Years – 10 Years
Healthy volunteers
Not accepted

Summary

Children frequently exhibit pre-MRI anxiety that can cause motion, repeated sequences, prolonged room time, and exposure to sedation. Orientation with Virtual Reality (VR) may reduce anxiety by familiarizing children with the scanner environment and expected sensations. This single-center, three-arm randomized clinical trial evaluates whether (1) Home+Booster VR (an age-appropriate 360° VR module at home \~24-48 hours before MRI plus a brief on-site refresher immediately before positioning), (2) Pre-Scan VR only (same module viewed on site immediately before positioning), or (3) Usual Care without VR improves MRI image quality and tolerance in children undergoing their first-ever MRI. Eligible participants are children scheduled for clinically indicated, non-emergent MRI with no prior MRI experience. Major exclusions comprise MRI contraindications; contraindications to VR use (e.g., uncontrolled epilepsy or severe motion sickness); uncorrected severe visual/hearing impairment precluding VR viewing; and inability to provide assent/consent. After consent/assent, participants are randomized 1:1:1 to one of three arms. Anticipated enrollment is \~150 total (\~50 per arm; up to 60 per arm if feasible). All arms receive routine safety procedures and child-oriented coaching per institutional practice. The VR module (\~8-10 minutes) provides a 360° walkthrough of the MRI process (sounds, positioning, keeping still) with child-focused narration. Adherence (timestamps/duration) is recorded where applicable. The primary outcome is motion artifact rated on a predefined ordinal scale by a board-certified radiologist masked to allocation; the proportion achieving diagnostic quality without repeat/sedation is also reported. Key secondary outcomes include sedation requirement, number of repeated sequences, total scan room time, scan completion without interruption, and change in child anxiety (mYPAS-SF). Additional prespecified measures include comfort/calmness Likert scales, Wong-Baker FACES pain, CEMS during scan, parent state anxiety, satisfaction VAS, physiologic vitals (heart rate, blood pressure, SpO₂) at defined peri-scan time points, observed crying and movement durations, and total scan duration. The trial uses parallel assignment with allocation concealment and masked outcome assessment. Analyses follow intention-to-treat with prespecified subgroup exploration by age bands (5-7 vs 8-10). Recruitment is planned for October 6, 2025; primary completion is expected within approximately three months.

Detailed description

Rationale. Pre-procedural anxiety in pediatric MRI is a well-recognized driver of motion, repetition of sequences, longer scanner occupancy, and sedation exposure. Brief, developmentally tailored exposure using a 360° VR module is hypothesized to reduce anxiety and movement through familiarization with scanner sounds, spatial constraints, and behavioral expectations. Design Overview. Single-center, three-arm randomized clinical trial with parallel assignment and allocation concealment. Participants with no prior MRI experience are randomized 1:1:1 to Home+Booster VR, Pre-Scan VR only, or Usual Care. Outcome assessment is masked to allocation. Analyses follow intention-to-treat; per-protocol summaries are planned as supportive. Intervention Content and Delivery. The VR module (\~8-10 minutes) depicts arrival, positioning, acoustic noise, and the importance of remaining still. Narration and visuals are age-appropriate. * Home+Booster VR: module viewed at home approximately 24-48 hours before MRI (re-view permitted), plus a brief on-site refresher immediately before positioning. * Pre-Scan VR only: module viewed only on site immediately before positioning. * Usual Care: standard institutional preparation without VR. Routine safety procedures and child-oriented coaching are applied uniformly across arms. Adherence and Fidelity. Where available, platform logs capture timestamps and duration of module exposure (home and on-site). Staff document completion of on-site viewing and any technical issues. Periodic fidelity checks ensure consistent delivery. Randomization, Masking, and Allocation Concealment. Randomization is performed via a concealed sequence (computer-generated permuted blocks). Allocation is revealed to staff immediately prior to preparation. Image-quality ratings are performed by a board-certified radiologist masked to allocation. Staff involved in VR delivery are not masked; contact with the assessor is minimized. Safety Monitoring. VR is paused or discontinued for nausea, dizziness, or discomfort. Standard MRI safety screening is conducted per institutional policy. Adverse events related to VR exposure or MRI are recorded and reviewed by the study team; serious events are reported per institutional requirements. Data Handling. Data are captured in secure, access-controlled case report forms with predefined range checks. Personally identifiable information is stored separately from analytic datasets. Quality control includes double-entry checks for a subset and automated logic checks. Statistical Approach (brief). Descriptive statistics summarize baseline characteristics and feasibility metrics (e.g., adherence to the module). The primary endpoint (motion artifact score) is analyzed under intention-to-treat using appropriate ordinal or dichotomous models specified in the statistical analysis plan. Prespecified subgroup analyses examine age bands (5-7 vs 8-10). Multiplicity control procedures are detailed in the analysis plan. Missing data strategies are predefined and documented. Timeline. Recruitment is planned to commence October 6, 2025. Enrollment and follow-up are expected to conclude within approximately three months, subject to scheduling logistics and scanner availability.

Conditions

Interventions

TypeNameDescription
BEHAVIORALVirtual Reality Orientation (Home+Booster)Age-appropriate 360° VR module (\~8-10 min) showing MRI room, sounds, positioning, and the importance of keeping still; viewed at home 24-48 h pre-scan on a smartphone/VR viewer (or flat 360° if no headset), plus a brief booster view on site immediately before positioning (\~3-5 min refresher).
BEHAVIORALVirtual Reality Orientation (Pre-Scan Only)The same 360° VR module (\~8-10 min) viewed once on site in the MRI area immediately before positioning; no home exposure.
OTHERUsual Care (No VR)Standard institutional pediatric MRI preparation (verbal explanation, hearing protection demo, child-friendly coaching) without VR.

Timeline

Start date
2025-10-06
Primary completion
2026-01-15
Completion
2026-03-31
First posted
2025-10-02
Last updated
2025-10-02

Source: ClinicalTrials.gov record NCT07203716. Inclusion in this directory is not an endorsement.