Trials / Not Yet Recruiting
Not Yet RecruitingNCT06884228
Effects of Vibrating Mesh Nebulisation in Patients With COPD During Non-invasive Ventilation (VMN-NIV)
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 12 (estimated)
- Sponsor
- Guy's and St Thomas' NHS Foundation Trust · Academic / Other
- Sex
- All
- Age
- 18 Years – 80 Years
- Healthy volunteers
- Not accepted
Summary
Assessment of the effects of vibrating mesh nebulisation versus jet nebulisation on the electrical activity of the muscles involved in breathing (neural respiratory drive), breathing mechanics (respiratory impedance measured by forced oscillation technique), respiratory flow, heart rate and rhythm, spirometry and breathlessness symptoms in patients with chronic obstructive pulmonary disease who require non-invasive ventilation.
Detailed description
Background Chronic obstructive pulmonary disease (COPD) remains a leading cause of morbidity and mortality in the United Kingdom. Acute exacerbations of COPD (AECOPD) frequently necessitate hospitalisation, with standard treatment comprising nebulised bronchodilators, antibiotics, and systemic corticosteroids. Approximately 20% of patients hospitalised with AECOPD require non-invasive ventilation (NIV) to manage decompensated hypercapnic respiratory failure, often necessitating concurrent administration of nebulised therapy. Home NIV use is increasing among COPD patients to improve respiratory symptoms, quality of life, reduce hospitalisation frequency, and enhance survival. These patients may also require nebulised bronchodilator therapy during NIV, particularly when managing acute exacerbations not severe enough to warrant hospitalisation. Currently, two nebulisation modalities are used as standard of care for patients on NIV: Jet nebulisation (JN) - the conventional delivery method Vibrating mesh nebulisation (VMN) - a newer technology that utilises a mesh membrane oscillating at high frequency to produce drug-carrying droplets of predetermined size VMN has been developed to optimise drug delivery in various patient populations, including those who are spontaneously breathing, receiving invasive mechanical ventilation, or on NIV. This technology is designed to enhance pulmonary drug deposition while minimising residual drug volume post-nebulisation. Previous research has demonstrated that VMN achieves superior pulmonary drug deposition during NIV compared to JN in both healthy subjects and stable COPD patients. VMN has also been shown to produce greater improvements in forced expiratory volume in one second (FEV₁) among hospitalised patients. However, the comparative effects of these nebulisation methods on physiological parameters such as neural respiratory drive and respiratory system impedance during NIV in COPD patients with chronic respiratory failure remain unexplored. Study Objective This pilot randomised crossover trial aims to compare the physiological effects of vibrating mesh versus jet nebulisation of salbutamol during NIV in patients with chronic respiratory failure due to COPD. Methods Study Design A randomised crossover trial with participants receiving both interventions with a 48-hour washout period between treatments. Participants We will recruit 12 patients with COPD currently receiving NIV under the care of the Lane Fox Unit. All participants will provide written informed consent prior to study procedures. Procedures Following consent, we will record baseline data including: NIV settings Anthropometric measurements Arterial blood gas analysis Clinical observations Participants will be randomised to receive salbutamol via either VMN or JN during NIV. We will measure the following parameters at multiple time points within one hour after nebulisation: Neural respiratory drive via parasternal electromyography Spirometry Respiratory impedance (mechanics of breathing) Participants will self-report breathlessness using both a numerical scale and a validated scale. After a minimum of 48-hour washout period, participants will return to repeat the protocol with the alternative nebuliser type.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Vibrating mesh nebulisation | Vibrating mesh nebulisation (VMN) uses a mesh membrane that oscillates at high frequency (typically 128kHz) to produce a stream of drug-carrying droplets of pre-determined size to be inhaled |
| DEVICE | Jet nebuliser | Jet nebulisers use the flow of a gas (air or oxygen) to draw medication up through a capillary tube to generate small particles to be inhaled. |
Timeline
- Start date
- 2025-03-21
- Primary completion
- 2026-05-01
- Completion
- 2026-05-01
- First posted
- 2025-03-19
- Last updated
- 2025-03-19
Locations
1 site across 1 country: United Kingdom
Source: ClinicalTrials.gov record NCT06884228. Inclusion in this directory is not an endorsement.