Trials / Completed
CompletedNCT06216119
Intrarenal Venous Flow Change During Fluid Removal in Critically Ill Patients: A Prospective Exploratory Study
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 52 (actual)
- Sponsor
- Mahidol University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This clinical trial aims to study intrarenal venous flow patterns change, VExUS score change, and LUS score change during fluid removal treatment in critically ill patients
Detailed description
Background: In patients with heart failure, intrarenal venous flow patterns could change depending on the level of congestion and was strongly correlated with death from cardiovascular disease and unplanned hospitalization. However, the findings may differ in patients with sepsis in the intensive care unit. In this case, Intrarenal venous flow patterns were not associated with Central Venous Pressure but were associated with Acute Kidney Injury and death. This suggests that intrarenal venous flow patterns may serve as an indicator of renal congestion and could be a feasible bedside tool to predict various clinical implications. In addition, Point-of-care ultrasound (POCUS) techniques such as Venous Excess Ultrasound (VExUS) and Lung Ultrasound (LUS) provide non-invasive assessments of fluid status and venous congestion. This study evaluates changes in VExUS and LUS scores during fluid removal to predict clinical outcomes in critically ill patients. Objective: We aimed to study intrarenal venous flow patterns change, VExUS score change, and LUS score change during fluid removal treatment in critically ill patients. Methods: * After enrollment, patients will undergo baseline Doppler ultrasonography to evaluate intrarenal venous flow patterns and LUS before the initiation of fluid removal through diuretic therapy or renal replacement therapy. * After patients received fluid removal therapy, they will receive continuous ultrasonography monitoring within 24, 48, and 72 hours, along with data collection. Researchers will collect data about * intrarenal venous flow patterns change, Venous Excess Ultrasound (VExUS) score change, and LUS score change during fluid removal treatment * establish a correlation between alterations in intrarenal flow patterns, VExUS score, and LUS score as well as other clinical data (Central venous pressure, Cumulative fluid balance) and clinical implications (Renal replacement therapy free day, Ventilator free day, length of Intensive care unit stay).
Conditions
Timeline
- Start date
- 2024-01-23
- Primary completion
- 2024-09-16
- Completion
- 2024-10-13
- First posted
- 2024-01-22
- Last updated
- 2025-05-29
Locations
1 site across 1 country: Thailand
Source: ClinicalTrials.gov record NCT06216119. Inclusion in this directory is not an endorsement.