Trials / Recruiting
RecruitingNCT05988645
Performance and Safety of MiWEndo-assisted Colonoscopy (MiWEndo II)
Performance and Safety of MiWEndo-assisted Colonoscopy: MiWEndo II (Pivotal Study)
- Status
- Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 50 (estimated)
- Sponsor
- MiWEndo Solutions S.L. · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The study involves the planned use of a new microwave-based device during colonoscopy procedures in 50 patients to assess the performance and safety of its use for detection of colorectal polyps and lack of normal clinical practice modification. The device is a final design version, which has been previously tested in several preclinical studies (including phantom studies, an ex vivo study with human tissues, and an in vivo study with porcine model) and in a pilot study in humans (NCT05477836)
Detailed description
This study is designed as a single-center prospective, non-comparative study in 50 patients, whereby data will be subject to an analytical description, rather than to a statistical treatment (refer to Statistical design and analysis). In this study the principal aims are to assess the performance and safety of the device for the detection of colorectal polyps when used as an accessory to colonoscopy. Relevant claims to verify in this study are that the device will detect in first instance polyps not detected initially with the endoscopic image and can be used without ADEs, without any change in the current clinical practice, as well as without any major difficulty by the endoscopist, neither in the preparation nor in the use of the device during exploration. In addition, in the first phase of the study (n=15 patients), the study aims to gather real clinical data with the use of the device to optimise the processing software that will be key to demonstrate MiWEndo\'s performance on the second part of the study (n=35 patients). Consequently, principal and secondary objectives of this investigation, are: Principal objectives: * To assess the performance of MiWEndo-assisted colonoscopy in the detection of colorectal polyps. * To assess the safety of MiWEndo-assisted colonoscopy. Secondary objectives: * To assess the perception of difficulty by the endoscopist when the device is used. * To provide exploratory analysis of differences in MiWEndo-assisted colonoscopy in different groups of patients to guide future RCT. * To assess the patient's comfort.
Conditions
- Colorectal Cancer
- Colorectal Polyp
- Colorectal Adenoma
- Colorectal Adenomatous Polyp
- Colorectal Adenocarcinoma
- Colorectal Neoplasms
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | MiWEndo System | All colonoscopies will be performed with high-definition technology. The MiWEndo System will be fitted to the tip of the endoscope before colonoscopy is started and connected to the microwave processor unit. Endoscopies will be performed by experienced endoscopists who will be previously trained on the use of the MiWEndo System. The MiWEndo Analyzer will be managed by the assistant. At the beginning of the extubation, the MiWEndo System will be turned on and the endoscopist will put music headphones on (blind to the results of MiWEndo). In case one of them identifies a polyp, the exploration will be stopped and check if it has been detected by the alternative method as well. All the polyps will be resected and sent to the Pathological Department for histological analysis following the usual clinical practice. A stopwatch will be used to measure both total procedure time and withdrawal time. |
Timeline
- Start date
- 2023-08-01
- Primary completion
- 2025-12-29
- Completion
- 2025-12-29
- First posted
- 2023-08-14
- Last updated
- 2025-09-29
Locations
1 site across 1 country: Spain