Clinical Trials Directory

Trials / Unknown

UnknownNCT05355649

Aspiration Technique-based Device for Preterm Labor

Impact of a New Aspiration Technique-based Device for Assessment of Cervical Stiffness in Pregnant Women With Symptoms of Preterm Labour

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
100 (estimated)
Sponsor
Federico II University · Academic / Other
Sex
Female
Age
18 Years – 50 Years
Healthy volunteers
Not accepted

Summary

Premature birth (PTB, birth before 37 weeks of pregnancy) is a global, yet unsolved, problem. With a global amount of approximately 15 M babies born prematurely, PTB is the leading cause of perinatal morbidity and mortality in many countries. Furthermore, premature babies often have complicated medical problems, especially those born very early. Some women spontaneously deliver prematurely without any symptom or sign of the imminent labor, whereas others present with symptoms of preterm labor (PTL). In the latter case, clinicians can intervene and treat the woman with tocolytics and antenatal corticosteroids in order to accelerate fetal lung maturation and reduce the risk of respiratory distress syndrome. However, one of the major challenges in the management of women presenting with symptoms of PTL is to distinguish between true and false PTL with the existing clinical methods (digital examination or transvaginal cervical length assessment). In fact, over 50% of the women presenting with PTL symptoms do not deliver prematurely and are still unnecessarily hospitalized and treated with corticosteroids as well as tocolytics, and only less than 10% of women give birth within 7 days of presentation. Unnecessary treatments and hospitalizations also result in increased health costs. Thus, there is a need for more accurate methods and tools to evaluate the cervical maturation status as indication of imminent labor in order to avoid unnecessary hospital admissions and therapy. Recently, cervical stiffness has been evaluated as more reliable tool for prediction of spontaneous preterm birth. Cervical stiffness can be evaluated using ultrasound by cervical elastography , but also by an aspiration technique-based method with a novel CE-marked device, the Pregnolia System. Thus, the aims of this study are to evaluate: * if the cervical stiffness measured with the Pregnolia System can differentiate between women with true PTL and those with false PTL, * if the knowledge of cervical stiffness improves the detection of women at true risk of spontaneous preterm birth in combination or over state of the art (e.g. cervical length on TVUS).

Detailed description

Premature birth (PTB, birth before 37 weeks of pregnancy) is a global, yet unsolved, problem. With a global amount of approximately 15 M babies born prematurely, PTB is the leading cause of perinatal morbidity and mortality in many countries. Furthermore, premature babies often have complicated medical problems, especially those born very early. Some women spontaneously deliver prematurely without any symptom or sign of the imminent labor, whereas others present with symptoms of preterm labor (PTL). In the latter case, clinicians can intervene and treat the woman with tocolytics and antenatal corticosteroids in order to accelerate fetal lung maturation and reduce the risk of respiratory distress syndrome. However, one of the major challenges in the management of women presenting with symptoms of PTL is to distinguish between true and false PTL with the existing clinical methods (digital examination or transvaginal cervical length assessment). In fact, over 50% of the women presenting with PTL symptoms do not deliver prematurely and are still unnecessarily hospitalized and treated with corticosteroids as well as tocolytics, and only less than 10% of women give birth within 7 days of presentation. Unnecessary treatments and hospitalizations also result in increased health costs. Thus, there is a need for more accurate methods and tools to evaluate the cervical maturation status as indication of imminent labor in order to avoid unnecessary hospital admissions and therapy. Recently, cervical stiffness has been evaluated as more reliable tool for prediction of spontaneous preterm birth. Cervical stiffness can be evaluated using ultrasound by cervical elastography , but also by an aspiration technique-based method with a novel CE-marked device, the Pregnolia System. Thus, the aims of this study are to evaluate: * if the cervical stiffness measured with the Pregnolia System can differentiate between women with true PTL and those with false PTL, * if the knowledge of cervical stiffness improves the detection of women at true risk of spontaneous preterm birth in combination or over state of the art (e.g. cervical length on TVUS).

Conditions

Interventions

TypeNameDescription
DEVICEPREGNOLIA SYSTEMThe Pregnolia System is composed of two products: an active device (Pregnolia Control Unit) and a single-use sterile probe (Pregnolia Probe). The intended use of the Pregnolia System is to provide information about the mechanical properties of the uterine cervix by assessing the tissue stiffness through a proxy parameter (the closing pressure, denominated CSI, or Cervical Stiffness Index, in mbar). The Pregnolia System is intended to be used in conjunction with the information obtained from the clinical evaluation of the patient and in addition to other standard examinations.

Timeline

Start date
2022-04-08
Primary completion
2022-09-01
Completion
2022-12-01
First posted
2022-05-02
Last updated
2022-05-02

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT05355649. Inclusion in this directory is not an endorsement.