Trials / Unknown
UnknownNCT05328544
Reconstruction of the Anterior Cruciate Ligament of the Knee Joint, by the Method of Stabilization of the Screw With a Bioabsorbable Method, With or Without the Use of Autogenous Spongiform Bone Grafts.
Clinical and Comparative Evaluation of the Results of Autograft Healing of the Tendon of the Semitendinus Muscle in the Tibial Canal, After Reconstruction of the Anterior Cruciate Ligament of the Knee Joint, by the Method of Stabilization of the Screw With a Bioabsorbable Method, With or Without the Use of Autogenous Spongiform Bone Grafts.
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 60 (estimated)
- Sponsor
- eMKa MED Medical Center · Academic / Other
- Sex
- All
- Age
- 18 Years – 65 Years
- Healthy volunteers
- Not accepted
Summary
Clinical and comparative evaluation of the results of autograft healing of the tendon of the semitendinus muscle in the tibial canal, after reconstruction of the anterior cruciate ligament of the knee joint, by the method of stabilization of the screw with a bioabsorbable method, with or without the use of autogenous spongiform bone grafts.
Detailed description
Assessment of the results of autograft healing of the tendon of the semitendinus muscle in the tibial canal, after the reconstruction of the anterior cruciate ligament (ACL) of the knee joint using the arthroscopic technique, with the method of tibial stabilization with a bioabsorbable screw (Arthrex) with the use of autogenous transplantation of spongy bone, drilling of the tibial canal inserted into the tibial canal prior to insertion of the screw. The detailed objectives are: comparison of the treatment results - healing and reconstruction of the autograft of the semitendinus tendon in the tibial canal of the knee joint, obtained in the study groups using two methods: A- stabilization of the tibial attachment with a bioabsorbable screw (Arthrex) with simultaneous application to the tibial canal of autogenous cancellous bone grafts taken during the drilling of this canal and B- stabilization of the tibial insertion with a bioabsorbable screw (Arthrex) without simultaneous application of autogenous cancellous bone grafts to the tibial canal.
Conditions
- Anterior Cruciate Ligament Injuries
- Anterior Cruciate Ligament Rupture
- Anterior Cruciate Ligament Tear
- Knee Injuries
- Knee Ligament Injury
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | ACL reconstruction of the knee joint by arthroscopic technique, with the tibial fixation method using a bioabsorbable screw (Arthrex) with the use of autogenous cancellous bone grafts | Reconstruction of the anterior cruciate ligament (ACL) of the joint the knee stabilization method, a bioabsorbable screw with the use of an autogenous spongy bone graft taken during drilling of the tibial canal into the tibial canate before inserting the screw. |
| PROCEDURE | ACL reconstruction of the knee joint by arthroscopic technique, with the tibial fixation method using a bioabsorbable screw (Arthrex) without the use of autogenous cancellous bone grafts | Reconstruction of the anterior cruciate ligament (ACL) of the joint the knee stabilization method, a bioabsorbable screw without the use of an autogenous spongy bone graft taken during drilling of the tibial canal into the tibial canate before inserting the screw. |
Timeline
- Start date
- 2021-08-13
- Primary completion
- 2022-08-13
- Completion
- 2022-08-13
- First posted
- 2022-04-14
- Last updated
- 2022-04-14
Locations
1 site across 1 country: Poland
Source: ClinicalTrials.gov record NCT05328544. Inclusion in this directory is not an endorsement.