Trials / Completed
CompletedNCT03077204
BIO4 Clinical Case Study: Cervical Spine
Clinical and Radiographic Outcomes of BIO4 Bone Matrix in Patients Undergoing 1 or 2-Level Anterior Cervical Discectomy and Fusion Surgery
- Status
- Completed
- Phase
- Phase 4
- Study type
- Interventional
- Enrollment
- 20 (actual)
- Sponsor
- Seton Healthcare Family · Academic / Other
- Sex
- All
- Age
- 19 Years
- Healthy volunteers
- Not accepted
Summary
The goal of this study is to investigate the efficacy of BIO4 bone matrix in patients undergoing 1 or 2-level Anterior Cervical Discectomy and Fusion (ACDF) spine surgery. Specifically, the study aims to collect the data for ACDF model utilizing BIO4 with Bio AVS Cervical Allograft (with graft window).
Detailed description
This is a prospective study with the intent to investigate the efficacy of BIO4 bone matrix in patients undergoing 1 or 2-level Anterior Cervical Discectomy and Fusion (ACDF) spine surgery. At the time a patient is scheduled for surgery, the patient's chart will be evaluated for inclusion/exclusion criteria. If a patient meets the criteria for the study, the study will be explained to the patient and consent obtained. Investigators will utilize the BIO4 on label as a 361 HCT/P (human cell, tissue and cellular and tissue-based product) for homologous use for the repair, replacement or reconstruction of bone defects. Interbody fusion (1 or 2-level fusion) in conjunction with an allograft (hct/p) interbody spacer (anterior approach in the cervical spine with hardware) will be utilized. Investigators will also use the Aviator Anterior Cervical Plating System for anterior intervertebral screw fixation of the cervical spine at levels C2-T1. The Aviator Anterior Cervical Plating System is intended for use as an aid in cervical spinal fusion and is intended for unilateral fixation. The Aviator plates are intended to be used with the Aviator bone screws. Study Outcomes: * Radiological assessment (cervical spine x-ray and if needed, computed tomography (CT) at 1 year follow up)of fusion as the primary endpoint * Arthrodesis rates assessed using CT (1 year follow up, if needed) and Anterior-Posterior (AP), lateral and dynamic flexion-extension cervical spine x-rays pre-operative (pre-op), post-operatively (post-op) 2\~4 weeks (10\~34 days post op), 3 months (83\~97 days post-op), 6 months (173\~187 days post-op) and 1 year post-op (351\~379 days post op, primary data point outcome) * Revision rates * Outcome scores: Visual Analog Scale (VAS) and Neck Disability Index (NDI) pre-op, post-op 2\~ 4weeks, 3 months, 6 months and 1 year. The null hypothesis is that in ACDF model, the clinical and radiographic outcomes of utilizing BIO4 bone matrix with Bio AVS Cervical Allograft are equivalent to historical high level published data of similar product (Data reported in Meta-analysis ACDF obtained from FDA disc arthroplasty trials).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| BIOLOGICAL | 1 or 2-Level ACDF utilizing BIO4 with Bio AVS Cervical Allograft (with graft window). | The study will utilize the BIO4 on label as a 361 HCT/P (human cell, tissue and cellular and tissue-based product) for homologous use for the repair, replacement or reconstruction of bone defects. Interbody fusion (1 or 2-level fusion) in conjunction with an allograft (hct/p) interbody spacer (anterior approach in the cervical spine with hardware). Investigators will also use the Aviator Anterior Cervical Plating System for anterior intervertebral screw fixation of the cervical spine at levels C2-T1. The Aviator Anterior Cervical Plating System is intended for use as an aid in cervical spinal fusion and is intended for unilateral fixation. The Aviator plates are intended to be used with the Aviator bone screws. |
| DEVICE | Aviator Anterior Cervical Plating System | The study will utilize the BIO4 on label as a 361 HCT/P (human cell, tissue and cellular and tissue-based product) for homologous use for the repair, replacement or reconstruction of bone defects. Interbody fusion (1 or 2-level fusion) in conjunction with an allograft (hct/p) interbody spacer (anterior approach in the cervical spine with hardware). Investigators will also use the Aviator Anterior Cervical Plating System for anterior intervertebral screw fixation of the cervical spine at levels C2-T1. The Aviator Anterior Cervical Plating System is intended for use as an aid in cervical spinal fusion and is intended for unilateral fixation. The Aviator plates are intended to be used with the Aviator bone screws. |
Timeline
- Start date
- 2017-04-06
- Primary completion
- 2020-01-30
- Completion
- 2020-01-30
- First posted
- 2017-03-10
- Last updated
- 2022-01-14
- Results posted
- 2022-01-14
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated drug study
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT03077204. Inclusion in this directory is not an endorsement.