AL-2 MP-1 (Polyimide) Acetabular Liner

Total Hip Replacement - MP-1 Acetabular Liner

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
M.M.A Tech Ltd. · Industry
Sex
All
Age
21 Years – 90 Years
Healthy volunteers
Accepted

Summary

M.M.A.TECH Ltd. product is an Acetabular Liner Family produced of an advanced polyimide - MP-1™. M.M.A.TECH Ltd. produces the Liners according to EN ISO 13485:2012 approved manufacturing process and supplies them to the customer. The aim of this study is to evaluate, in the frame of PMCF, the safety and performance of using AL-X MP1 Polyimide Acetabular liners in Total Hip Replacement surgery by clinical following up of patients for a period of 2 years .

Detailed description

The procedure involves removal of the diseased parts of the joint, that is the damaged cartilage and adjacent bone, and replacing them with artificial parts which closely resemble in structure and/or function the removed native parts. The artificial parts fit onto the reshaped bone and are fixed either with bone cement (e.g., polymethylmethacrylate) and press fit of the part(cemented), or by self-anchorage with bone ingrowth to its porous surface(cementless). The design of the artificial parts may include a stem, a keel or pegs, which fit onto the medullary canal of the bone or into a hole pre-prepared in the bone. An artificial part may fit loosely and be fixed with bone cement, press-fit for self- anchorage or include extendible anchors which are retracted upon placement and extended thereafter so as to secure the implant in place. Following fixation of the components, the joint is reduced and the soft tissue tension is appropriately checked to reassure stability of the joint. The MP-1™ acetabular liner will be tapper locked in acetabular metal shells to resurface the acetabular socket in cementless total hip replacement. MMaTech Ltd will manufacture the liners to perfectly fit into the external metallic shell of the following sizes (mm): LINER CUP SIZE LINER SIZE HEAD Liner thickness AL-2MP132040 44-48 32 ID 40 OD 32 4 mm AL-2MP136044 50-54 36 ID 44 OD 36 4mm AL-2MP136048 56-66 36 ID 48 OD 36 6mm AL-2MP140048 56-66 40 ID 48 OD 40 4mm The MP-1™ Acteabular liners are intended to be used only against ceramic femoral heads- Biolox Delta

Conditions

Interventions

TypeNameDescription
DEVICEMP-1 Polymer on Ceramic Articulation systemMP-1 Polymer liner on Ceramic head

Timeline

Start date
2017-09-15
Primary completion
2018-09-01
Completion
2020-08-01
First posted
2015-07-21
Last updated
2017-12-20

Locations

1 site across 1 country: Israel

Source: ClinicalTrials.gov record NCT02503891. Inclusion in this directory is not an endorsement.