Clinical Trials Directory

Trials / Completed

CompletedNCT02450825

Comparison of Three Scores for Ultrasound Assessment and Monitoring of Pulmonary Aeration

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
77 (actual)
Sponsor
Centre hospitalier de l'Université de Montréal (CHUM) · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This study is designed to compare three ultrasound-based aeration scores that were previously validated in specific populations, and to assess their correlation with computed tomographic measurement of pulmonary aeration in a population with different pathologies. Hypothesis: The "Loss of Aeration Score" will be more accurate than a simplified version and another widely used score, the "Lung Ultrasound Score".

Detailed description

Assessment of lung aeration may have a great impact in the management of mechanical ventilation and follow-up of diverse lung pathologies. Computed tomographic scan is the gold standard method of lung aeration measurement but is rarely used because it requires transport of critically ill patients end exposes them to radiations. For these reasons, lung ultrasound would be an attractive alternative. Variants of different ultrasound-based aeration scores have been validated in different specific populations, but there is no comparison study that defines the more accurate score that should be used in a population with different pathologies. Methods: Patients undergoing a computed tomographic scan for dyspnea or hypoxemia will have a standardized lung ultrasound examination on Day 1. For mechanically ventilated patients only, a lung ultrasound examination will be repeated on Day 2 to 4. End expiratory lung volume will also be measured in mechanically ventilated patients on Day 1 and Day 2 to 4. Lung ultrasound images will be interpreted blindly. Correlation of ultrasound-based aeration scores will be done with lung aeration measured by computed tomographic images.

Conditions

Interventions

TypeNameDescription
PROCEDURELung ultrasound examination on Day 1 and Day 2 to 4A standardized lung ultrasound examination using the GE Vivid ultrasound system will be performed following the tomographic scan on Day 1 and repeated on Day 2 to 4. Correlation of ultrasound-based aeration scores will be done with lung aeration measured by computed tomographic images.
PROCEDURELung ultrasound examination on Day 1A standardized lung ultrasound examination using the GE Vivid ultrasound system will be performed following the tomographic scan on Day 1 only. Correlation of ultrasound-based aeration scores will be done with lung aeration measured by computed tomographic images.
DEVICEGE Vivid Ultrasound systemThe GE Vivid ultrasound system will be used for all lung ultrasound examinations performed in this study.

Timeline

Start date
2015-07-01
Primary completion
2017-02-01
Completion
2017-02-01
First posted
2015-05-21
Last updated
2017-03-03

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT02450825. Inclusion in this directory is not an endorsement.