STIT-2: Evaluation of Safety and Efficacy of Short-time TNI® Treatment in Patients With COPD and Hypercapnia
Evaluation of Safety and Efficacy of Short-time TNI® Treatment in Patients With COPD and Hypercapnia Acute Testing of Oxygen Demand Using TNI® vs. Standard Insufflation in COPD Patients With Hypercapnia at Rest
- Status
- Unknown
- Phase
- Phase 1
- Study type
- Interventional
- Enrollment
- 30 (estimated)
- Sponsor
- Medical University Innsbruck · Academic / Other
- Sex
- All
- Age
- 30 Years – 85 Years
- Healthy volunteers
- Not accepted
Summary
Evaluation of Safety and Efficacy of Short time TNI Treatment in Patients with COPD and hypercapnia. Acute testing of oxygen demand using TNI vs. standard oxygen application in stable COPD patients with hypercapnia.
Detailed description
TNI, the nasal insufflation of a high flow of warm, humidified air, is an extremely comfortable and uncomplicated alternative to numerous other approaches in non-invasive ventilation (NIV). Up to now, NIV therapy could only be applied by masks with the associated complications as patients could not tolerate high airflow delivered by a thin nasal cannula without humidification and warming, thus causing concomitant negative effects. The new therapy TNI shows a high rate of acceptance by children, too. At present, there are two different types of devices available for nasal insufflation in clinics: TNI 20s, an air humidifier for clinical compressed air, and the TNI20 oxy, an air humidifier for clinical compressed air, which can be combined with oxygen. TNI 20 oxy The system, which is unique throughout the world, is optimized for the application of flows of up to 20L/min and fulfils the minimum requirements of the "American Society of Testing and Materials" for a high flow air humidifier in the non-invasive application of 10 mg H2O/L (equivalent to about 60% rel. humidity at an ambient temperature of 22°C) for the air humidity. The warming of the air flow by 5-15°C can be adjusted relative to the ambient temperature. Condensation is prevented in the nasal applicator by heating the tube as far as the nostrils. The device automatically controls humidity and temperature depending on the prevailing ambient conditions. The TNI®20s can be attached to the hospital infrastructure by means of a standard pressure regulator. In another ongoing study (STIT-1) TNI 20 oxy was evaluated for its safety in COPD patients without hypercapnia. In a first interim analysis which included 14 patients high flow oxygen delivery was safe.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Nasal oxygen insufflation with a TNI® 20 oxy device | Nasal insufflation at a constant high flow of 15 L/min with oxygen addition starting at 0.5 L/min |
| DEVICE | Nasal insufflation of oxygen | Nasal insufflation of oxygen starting at at flow of 0.5 L/min. |
Timeline
- Start date
- 2011-12-01
- Primary completion
- 2013-12-01
- Completion
- 2013-12-01
- First posted
- 2012-09-26
- Last updated
- 2012-09-26
Locations
4 sites across 3 countries: Austria, Germany, Switzerland
Source: ClinicalTrials.gov record NCT01693146. Inclusion in this directory is not an endorsement.