Clinical Trials Directory

Trials / Unknown

UnknownNCT01446055

Safety and Efficacy Study of Autologous BM-MNC Processed by Two Methods for Treating Patients With Chronic Limb Ischemia

Transplantation of Autologous BM-MNC Processed by ResQ Separator and Conventional Manual Method for Patients With Chronic Limb Ischemia: a Multi-center Randomized Controlled Trial

Status
Unknown
Phase
Phase 1 / Phase 2
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
Xuanwu Hospital, Beijing · Academic / Other
Sex
All
Age
20 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Using autologous bone marrow mononuclear cells (BM-MNC) to treat patients with chronic limb ischemia has been proved safe and effective. However, processing bone marrow by Ficoll density gradient centrifugation is not only time consuming but also expensive. Manually processing of bone marrow also results in large variation in therapeutic cell quantity and quality which directly leads deviation of safety and efficacy of the cell therapy. This study is aiming to compare an automated bone marrow processing system with a conventional manual method in term of safety and efficacy.

Detailed description

Using autologous bone marrow mononuclear cells (BM-MNC) to treat patients with chronic limb ischemia has been proved safe and effective. However, processing bone marrow by Ficoll density gradient centrifugation is not only time consuming but also expensive. Manually processing of bone marrow also results in large variation in therapeutic cell quantity and quality which directly lead deviation of safety and efficacy of the cell therapy. This study is aiming to compare an automated bone marrow processing system with a conventional manual method in term of safety and efficacy. ResQ system developed by Thermogenesis in USA provides an automatic cell processing system for bone marrow. The system takes less than 30 minutes to concentrate the therapeutic mononuclear cells including stem cells in a closed system without adding any additive such as separation reagent (Ficoll). The system also be able to be operated at point of care. The study is designed to prove no inferior of safety and efficacy of bone marrow cells processed by ResQ to those of cells using conventional manual method. The conventional manual method is involved Ficoll density gradient centrifugation and cell washing stems in an open system. Each of test arms (ResQ vs manual method) consists of 25 patients. The primary outcome is safety which is measured by cell treatment-related adverse events. The secondary endpoints include resting ankle-brachial pressure index (ABI)and toe brachial pressure index (TBI) , transcutaneous oxygen pressure (TcPO2), claudication distance, rest pain scale evaluation, collateral vessel scale, etc.

Conditions

Interventions

TypeNameDescription
DEVICEResQ processed bone marrow sampleAutologous bone marrow is processed with ResQ at point of care, prior to the transplantation
DEVICEFicoll conventional cell processing methodComparison of different cell processing methods

Timeline

Start date
2011-10-01
Primary completion
2012-04-01
Completion
2013-04-01
First posted
2011-10-04
Last updated
2011-10-12

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT01446055. Inclusion in this directory is not an endorsement.