Clinical Trials Directory

Trials / Not Yet Recruiting

Not Yet RecruitingNCT07532811

Evaluation of Perfusion and Ventilation Distribution in Children: a Pilot Study.

Feasibility Study of the Evaluation of Perfusion and Ventilation Distribution in Children : a Pilot Study

Status
Not Yet Recruiting
Phase
N/A
Study type
Interventional
Enrollment
20 (estimated)
Sponsor
Hospices Civils de Lyon · Academic / Other
Sex
All
Age
12 Years
Healthy volunteers
Not accepted

Summary

Electrical impedance tomography (EIT) is a recent monitoring technique that provides information on regional ventilation distribution. Following the injection of a hypertonic saline bolus, EIT can also assess regional pulmonary perfusion distribution, allowing evaluation of the ventilation/perfusion (V/Q) ratio. In adults, protocols for assessing perfusion distribution require the injection of 10 mL of a 7.5% or 10% NaCl solution or sodium bicarbonate over a few seconds. Studies have reported good hemodynamic tolerance, adequate image quality, and no significant changes in serum sodium levels. However, this volume and sodium load are not appropriate for small children. To date, no pediatric protocol exists for assessing pulmonary perfusion distribution and the ventilation/perfusion ratio using EIT. It is therefore proposed to conduct a pilot study to evaluate the feasibility of assessing pulmonary perfusion by EIT using a weight-adjusted bolus of hypertonic saline (NaCl or sodium bicarbonate).

Conditions

Interventions

TypeNameDescription
OTHEREvaluation of perfusion with Electrical impedance tomography using sodium chloride or sodium bicarbonateAll patients will undergo EIT monitoring (Enlight 2100, Timpel, Brazil) using a belt adjusted to the thoracic circumference. Ventilation distribution will be assessed with a tidal volume of 8 mL/kg. Following a breath hold, a saline solution (sodium chloride or sodium bicarbonate) will be injected over a few seconds. Perfusion distribution, as well as impedance signal variation, will be recorded using dedicated software (Timpel, Brazil). Data acquisition will be considered valid if the impedance signal variation induced by the saline solution injection is at least equivalent to the amplitude variation observed during ventilation with a tidal volume of 8 mL/kg. 2 measurements at 4 to 6-hours intervals with volume or concentration adjustment after the first injection if needed in the group 1

Timeline

Start date
2026-04-20
Primary completion
2028-04-20
Completion
2028-07-20
First posted
2026-04-16
Last updated
2026-04-16

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT07532811. Inclusion in this directory is not an endorsement.