Clinical Trials Directory

Trials / Active Not Recruiting

Active Not RecruitingNCT07394751

Clinical Performance of Bioactive Restorative Materials

Clinical Performance of Bioactive Restorative Materials in Occlusal Restorations: Preliminary Results of a Split-mouth Study

Status
Active Not Recruiting
Phase
N/A
Study type
Interventional
Enrollment
20 (actual)
Sponsor
Ege University · Academic / Other
Sex
All
Age
20 Years – 34 Years
Healthy volunteers
Not accepted

Summary

The aim of this clinical study is to evaluate the performance of three different bioactive restorative materials against a composite resin for a period of 9 months. This randomized, split-mouth, single-center trial was performed on patients having occlusal caries (ICDAS 3 and 4) in both molars of the same jaw. The restorative materials used were Tetric N-Ceram Bulk-fill (control, Ivoclar Vivadent, Liechtenstein), Stela (SDI, Australia), Cention Forte (Ivoclar) and Activa BioActive Restorative (Pulpdent, USA). The restorations were evaluated at baseline, 3-6 and 9-month according to FDI-2 criteria, in terms of functional, biological, and aesthetic parameters, by two experienced evaluators.

Detailed description

Objectives: To clinically evaluate the performance of three different bioactive restorative materials against a composite resin for a period of 9 months. Materials and Methods: This randomized, split-mouth, single-center trial was performed on patients having occlusal caries (ICDAS 3 and 4) in both molars of the same jaw. The restorative materials used were Tetric N-Ceram Bulk-fill (control, Ivoclar Vivadent, Liechtenstein), Stela (SDI, Australia), Cention Forte (Ivoclar) and Activa BioActive Restorative (Pulpdent, USA). The material allocation was randomly assigned by a drawing lot. The restorations were evaluated at baseline, 3-6 and 9-month according to FDI-2 criteria, in terms of functional, biological, and aesthetic parameters, by two experienced evaluators. Chi-square test was used to compare the variables in the categories. Mann-Whitney U test and paired T test compared the difference in scores for the groups (p\<0.05).

Conditions

Interventions

TypeNameDescription
PROCEDURETetric N Ceram Bulkfill applicationSelective enamel etching was performed with 37% phosphoric acid followed by a universal adhesive system application to all cavity surfaces and LED cured. The bulk-fill composite resin was placed in a single increment according to the manufacturer's recommendations and light-cured for 20 seconds. Excess material was removed using flame-shaped diamond finishing burs. Occlusion was assessed with articulation paper, and premature or undesirable contact points were adjusted as necessary.
PROCEDURECention Forte applicationA drop of Cention Primer was mixed in its wheel for 5 seconds and actively applied to the cavity for 10 seconds, followed by gentle air-drying. The Cention Forte capsule was then mixed for 15 seconds in a capsule mixer and placed in bulk into the prepared cavity using the manufacturer's delivery gun. Light curing was performed for 20 seconds with an LED unit (1300 mW/cm²; ZenoLite, President, Germany). Excess material was removed using flame-shaped diamond finishing burs. Occlusion was assessed with articulation paper, and any premature or undesirable contact points were adjusted accordingly. Final polishing was performed with OptraGloss polishing wheels (Ivoclar Vivadent) for 20 seconds.
PROCEDUREStela AutomixStela Primer was applied to the cavity surfaces and margins for 10 seconds. After a 5-second waiting period, the primer was gently air-dried for 2-3 seconds. The Stela Automix injector tip was then angled as needed and inserted into the cavity to deliver the material. The restoration was allowed to self-cure for 4 minutes. Occlusion was evaluated using articulation paper, and any premature or undesired contact points were adjusted as necessary. Final polishing was performed with OptraGloss polishing wheels (Ivoclar Vivadent) for 20 seconds.
PROCEDUREActiva BioActive RestorativeSelective enamel etching was performed with 37% phosphoric acid for 15 seconds, followed by thorough rinsing and air-drying. A universal adhesive system (Tetric N-Bond Universal, Ivoclar Vivadent) was applied to all cavity surfaces, including enamel, for 20 seconds, air-thinned, and light-cured for 20 seconds using an LED unit (1300 mW/cm²; ZenoLite, President, Germany). Following the manufacturer's instructions, the placement tip was inserted into the cavity using the dedicated placement gun, and the material was delivered in bulk. Light curing was performed for 20 seconds. Excess material was removed using flame-shaped diamond finishing burs. Occlusion was assessed with articulation paper, and premature or undesirable contact points were adjusted as needed. Final polishing was performed with OptraGloss polishing wheels (Ivoclar Vivadent) for 20 seconds.

Timeline

Start date
2024-11-01
Primary completion
2025-04-01
Completion
2026-11-01
First posted
2026-02-06
Last updated
2026-02-06

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT07394751. Inclusion in this directory is not an endorsement.