Trials / Not Yet Recruiting
Not Yet RecruitingNCT07289022
Clinical Evaluation of Flowable Monochromatic and Polychromatic Composite Resins in Posterior Restorations
Evaluation of the Color Matching Ability and Clinical Success of Flowable Monochromatic and Polychromatic Composite Resins in Posterior Restorations
- Status
- Not Yet Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 30 (estimated)
- Sponsor
- Istanbul University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This clinical study aims to investigate whether a single flowable composite resin system can achieve adequate color matching in posterior restorations and to compare it with a polychromatic composite system, which will serve as a control group. Clinical success will also be assessed using data obtained from the initial, six month, one-year, two-year, three-year, four-year, and five-year recall checks of the four different composite resin systems used in the study over a five-year period. L, a, and b parameters will be determined using the Vita Easyshade Compact (VITA Zahnfabrik, Bad Sackingen, Germany) Spectrophotometer device used in the study at the initial, half-year, one-year, two-year, three-year, four-year, and five-year intervals. Based on the obtained data, intraoral color changes will be determined using the CIEDE2000 color system. Each patient will be scanned with an intraoral scanner at each session. The hypothesis tested was that color matching and long-term clinical follow-up would be successful for all composite materials used in the study.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | dental composite | Overview: Four composite resin systems will be evaluated in posterior Class II restorations for color matching ability and clinical performance over 5 years. A polychromatic composite serves as the control; three single-shade/flowable or bulk-fill composites constitute the intervention arms. Isolation and preparation: All restorations will be performed under rubber dam using standardized cavity preparation and finishing/polishing protocols. Adhesive and etching: A single adhesive approach will be used across arms per manufacturer's instructions (self etch). Placement: Control (polychromatic): Layered placement per manufacturer. Single-shade/flowable/bulk-fill arms: Incremental or bulk placement within 2-5 mm as recommended. Light curing: Light-emitting diode (LED) light-curing units at 1200 mW/cm² for 20 s per increment; distance and angulation standardized. Assessment and follow-up: Baseline, 6 months, and annually up to 5 years. Color measured with Vita Easyshade |
Timeline
- Start date
- 2026-01-05
- Primary completion
- 2026-05-05
- Completion
- 2031-04-05
- First posted
- 2025-12-17
- Last updated
- 2025-12-17
Source: ClinicalTrials.gov record NCT07289022. Inclusion in this directory is not an endorsement.