Trials / Completed
CompletedNCT07162857
Guiding Fluid Resuscitation in Septic Shock: Ultrasound vs. Noninvasive Cardiac Output Monitoring
The Value of Critical Care Ultrasound and Noninvasive Cardiac Output Monitoring in Guiding Fluid Resuscitation for Septic Shock in the Emergency Department
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 60 (actual)
- Sponsor
- Mai Xiaowei · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This randomized controlled study investigates the value of critical care ultrasound and non-invasive cardiac output monitoring in guiding fluid resuscitation for patients with septic shock in the emergency department. A total of 60 patients are randomly assigned to receive either ultrasound-guided or NICOM-guided fluid management, with both groups receiving standard sepsis care according to the 2021 Surviving Sepsis Campaign guidelines. The study aims to evaluate whether these monitoring modalities can optimize hemodynamic management, improve prognosis, and support clinical decision-making in emergency settings. Primary and secondary outcomes include early resuscitation efficacy (time to achieve mean arterial pressure ≥65 mmHg and lactate clearance), total fluid volume within the first 6 hours, incidence of complications (pulmonary edema, renal injury, ARDS), length of stay in the emergency department and hospital, and 28-day mortality. By comparing these two approaches, this study seeks to provide evidence for selecting appropriate monitoring tools to achieve precise and individualized fluid resuscitation in septic shock.
Detailed description
This study is a prospective randomized controlled trial conducted in the Emergency Department of Guangzhou Panyu Central Hospital. Eligible adult patients with septic shock, admitted between july 2023 and july 2025, were enrolled after informed consent. Demographic and baseline clinical data, including age, gender, comorbidities, mean arterial pressure, baseline lactate, and vital signs, were collected at enrollment. A total of 60 patients were randomly assigned to one of two intervention groups using block randomization generated by SPSS software, with allocation concealed by sealed envelopes. * Critical Care Ultrasound Group: Patients underwent bedside ultrasound assessment, including inferior vena cava diameter and collapsibility index (IVC-CI), left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), ventricular wall motion, and pulmonary B-lines, to guide individualized fluid resuscitation. Ultrasound evaluations were repeated every 1-2 hours until resuscitation targets were achieved. * Non-Invasive Cardiac Output Monitoring (NICOM) Group: Patients received continuous hemodynamic monitoring using thoracic bioreactance technology. Parameters including cardiac output (CO), stroke volume (SV), stroke volume variation (SVV), and systemic vascular resistance (SVR) were continuously recorded and used to guide fluid therapy adjustments until resuscitation targets were achieved. In both groups, all patients received standard septic shock management based on the 2021 Surviving Sepsis Campaign guidelines, including early antibiotics, vasopressor therapy, and organ support. Outcomes recorded included total fluid volume within the first 6 hours, time to resuscitation targets, complications (e.g., pulmonary edema, renal injury, ARDS), emergency department and hospital length of stay, 28-day mortality, and adverse events (e.g., arrhythmias, anaphylaxis).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | non-invasive cardiac output monitoring | Monitoring commenced immediately after enrollment, with baseline parameters recorded after signal stabilization (≤5 minutes), including cardiac output (CO), stroke volume (SV), stroke volume variation (SVV), and systemic vascular resistance (SVR). The system automatically updated these parameters every 30 seconds and displayed them in real-time on the monitor screen. Fluid resuscitation was dynamically adjusted according to these continuous measurements until achieving the predefined therapeutic targets. |
| DEVICE | Ultrasonic technology | In the critical care ultrasound group, patients underwent immediate bedside This protocol ensured real-time, comprehensive evaluation of both cardiac function and fluid status to guide resuscitation.Ultrasound reassessment was performed every 1-2 hours to dynamically adjust both the volume and rate of fluid administration until predefined resuscitation targets were achieved. |
Timeline
- Start date
- 2023-07-05
- Primary completion
- 2025-07-31
- Completion
- 2025-07-31
- First posted
- 2025-09-09
- Last updated
- 2025-09-22
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT07162857. Inclusion in this directory is not an endorsement.