Clinical Trials Directory

Trials / Completed

CompletedNCT07068724

Management of Dentin Hypersensitivity in Patients With Periodontitis

Chemical and Laser Desensitization Approaches for Managing Dentin Hypersensitivity After Non-Surgical Periodontal Therapy: A Randomized Clinical Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
48 (actual)
Sponsor
Trakya University · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

A total of 62 patients diagnosed with Stage III-IV periodontitis underwent non-surgical periodontal therapy. At 24 hours post-treatment, patients were recalled to the clinic for reassessment using air-stimulated Visual Analog Scale (VAS) and Schiff Cold Air Sensitivity Scale measurements. Two teeth per patient were randomly selected based on a VAS score greater than 4 and a Schiff score of 2 or 3. A total of 52 patients who met the inclusion criteria were included in the study. This study was designed as a randomized, parallel clinical trial. The 52 patients were randomly allocated into three treatment groups: Group 1 received the desensitizing agent Gluma, Group 2 underwent Er,Cr:YSGG laser treatment, and Group 3 received a combination of Gluma and Er,Cr:YSGG laser therapy. Desensitizing agent applications were performed according to the designated treatment protocols.To assess changes in dentin hypersensitivity over time, patients were recalled for follow-up evaluations at 1 week, 2 weeks, 1 month, 2 months and 6 months post-application. The 6-month follow-up of the study was completed with 48 patients (16 patients for each study group). At each follow-up visit, air-stimulated VAS and Schiff scale measurements were employed to quantify hypersensitivity levels.

Conditions

Interventions

TypeNameDescription
COMBINATION_PRODUCTGluma Desensitizer and ER:CR;YSGG laser combinationParticipants in this group received both treatments: Gluma was applied using the same method as in Gluma, followed by Er,Cr:YSGG laser therapy using the same parameters and technique as in laser.
DEVICEEr,Cr:YSGG laserParticipants received Er,Cr:YSGG laser treatment (Water-Lase iPlusTM; Biolase® Technology Inc., Irvine, CA, USA). Laser parameters were set as follows: 2780 nm wavelength, 0.25 W power, 20 Hz frequency, 140 μs pulse duration, and 30 seconds exposure time. The MZ6 tip (660 μm diameter, 6 mm length, 1 mm spot size) was used in non-contact mode from a 1 mm distance, perpendicular to the dentin surface, with 0% water and 10% air spray. All laser applications followed international safety standards and protocols.

Timeline

Start date
2025-04-10
Primary completion
2025-10-10
Completion
2025-10-20
First posted
2025-07-16
Last updated
2025-12-16

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT07068724. Inclusion in this directory is not an endorsement.