SHort Of Pace - Heart Failure (SHOP-HF)
Pacemaker Implantation in Patients With Heart Failure With Preserved Ejection Fraction, Chronotropic Incompetence and Small Ventricular Volume. The SHOP-HF Trial
- Status
- Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 30 (estimated)
- Sponsor
- Fundación para la Investigación del Hospital Clínico de Valencia · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This study is designed as a multicenter, prospective, controlled, randomized, two-arms, cross-over, two parallel cohorts, efficacy Clinical research with CE-marked medical device . The crossover trial will be performed in a blind fashion, so each participant will be evaluated during both blinded pacing-on and pacing-off phases, each of which will last 3 months. The population includes patients with the diagnosis of stable HFpEF according to criteria of the European Society of Cardiology and New York Heart Association (NYHA) functional class II-III/IV, left ventricular hypertrophy with small ventricular volume, sinus rhythm with low basal heart rate and chronotropic incompetence (CI). All patients will undergo pacemaker implantation, and computer-generated randomization sequence previously designed will be used to allocate participants (in a 1:1 ratio) to receive: (a) programming of the pacemaker with pacing On followed by pacing Off in two periods of 3 months; or (b) programming of the pacemaker with pacing Off followed by pacing On in two periods of 3 months. The study will be conducted in three centers in Spain. Discounting the time due to staggered entry, the total duration of a patient's follow-up will be 7 months.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Dual-chamber cardiac pacemaker (Essentio MRI L111 Boston Scientific®), Single-chamber cardiac pacemaker (Essentio MRI L110 Boston Scientific®) | Dual-chamber cardiac pacemaker (Essentio MRI L111 Boston Scientific®), with rate-adaptive pacing of the right atrium. There will be an associated right atrial lead (INGEVITY™ MRI Pacing Lead Boston®) and right ventricular lead (INGEVITY™ MRI Pacing Lead Boston®). Single-chamber cardiac pacemaker (Essentio MRI L110 Boston Scientific®), with rate-adaptive pacing of the ventricles. There will be a right ventricular lead (INGEVITY™ MRI P Boston®). |
Timeline
- Start date
- 2025-06-17
- Primary completion
- 2026-06-01
- Completion
- 2026-06-01
- First posted
- 2025-05-28
- Last updated
- 2025-12-12
Locations
1 site across 1 country: Spain
Source: ClinicalTrials.gov record NCT06992089. Inclusion in this directory is not an endorsement.