Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06871969

Clinical Evaluation of EEG Device for the Triage of Stroke Patients in the Ambulance

Clinical Evaluation of Pre-hospital Stroke Triage Devices - Electroencephalography

Status
Recruiting
Phase
N/A
Study type
Interventional
Enrollment
275 (estimated)
Sponsor
Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA) · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Endovascular thrombectomy (EVT) is the standard treatment for large vessel occlusion (LVO) strokes, but it can only be performed in specialized hospitals. Since ambulance personnel cannot determine if a patient is eligible for EVT, 54% of LVO stroke patients are initially taken to non-EVT-capable hospitals, resulting in an average delay of 1 hour in time-to-EVT in the Netherlands. To reduce this delay, it is crucial for ambulance personnel to identify potential LVO stroke patients and directly transport them to EVT-capable hospitals. Dry electrode electroencephalography (EEG) has shown high diagnostic accuracy for detecting LVO strokes, but in 32% of patients, the EEG signal quality was too poor to analyze. To address this issue, TrianecT developed StrokePointer, a portable EEG-based triage device designed to collect and analyze EEG data in patients with suspected acute stroke. The objective of this study is to validate the effectiveness and safety of StrokePointer in detecting LVO stroke among patients with a suspected stroke in the pre-hospital setting.

Detailed description

RATIONALE Endovascular thrombectomy (EVT) is the standard treatment for large vessel occlusion (LVO) stroke. However, EVT can only be performed in specialized hospitals and its effect on functional outcome rapidly decreases with passing time (time = brain). Since ambulance personnel cannot determine whether a patient has a stroke that is eligible for EVT, 54% of patients with an LVO stroke are primarily presented at a non-EVT capable hospital. These patients then require interhospital transfer, resulting in average delay in time-to-EVT of 1 hour in the Netherlands. Therefore, providing ambulance personnel with tools to identify patients with a possible LVO stroke in the ambulance, allowing direct transport to an EVT capable hospital, is much needed. Dry electrode electroencephalography (EEG) has shown to have a high diagnostic accuracy for LVO stroke detection among patients with a suspected stroke (area under the receiving operating curve \[AUC\]: 0.91). However, in 32% of patients EEG signal quality was too poor to analyse. A new portable EEG-based triage device (StrokePointer) has been developed by TrianecT with the aim to collect and analyse EEG data in patients suspected of acute stroke. In this study, we intend to validate the safety and effectiveness of the device. HYPOTHESIS: 1. StrokePointer device can measure EEG data of sufficient quality in \>85% of patients, and has a good diagnostic accuracy (AUC\>0.8) for LVO stroke detection in the pre-hospital setting. 2. Usability of StrokePointer device is rated as "good" on average by ambulance personnel. 3. StrokePointer is safe to use in an acute care setting. OBJECTIVE Primary objective is to validate the data quality and diagnostic accuracy of StrokePointer to detect LVO stroke among patients with a suspected stroke in the pre-hospital setting. STUDY DESIGN CROSSROADS-EEG is an investigator-initiated, prospective, multi-centre cohort study. STUDY POPULATION Adult patients with a suspected stroke, onset of symptoms (or last seen well) \<24 hours in the pre-hospital setting. INTERVENTION A single measurement with a dry electrode headset EEG (approximately 2 minutes recording duration) will be performed in each patient. Clinical and radiological data will be collected. EEG data will be acquired with the improved TrianecT EEG device, StrokePointer. MAIN STUDY END POINTS * Proportion of patients with a technically successful EEG dataset: at least 20 seconds of usable EEG (at least 3 electrodes with good skin-electrode quality on either side, no movement artifacts, no muscle artifacts) within a measurement time of 3 minutes. * Diagnostic accuracy of StrokePointer for LVO stroke among patients with a suspected stroke, as measured with AUC as well as sensitivity and specificity.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTDry electrode EEGA single dry electrode electroencephalography (EEG) will be performed in each patient that is included in this study. EEG data will be acquired with Strokepointer (TrianecT B.V., Utrecht, The Netherlands). StrokePointer is a portable EEG acquisition and analysis device. The device consists of three parts: (1) StrokePointer headset with dry electrodes to measure EEG data, (2) Portable StrokePointer suitcase that contains a mobile computing device (Android phone), CE-marked (IIa) EEG amplifier and storage compartments and (3) Software to acquire, analyse and upload EEG data.

Timeline

Start date
2025-07-01
Primary completion
2026-12-01
Completion
2026-12-01
First posted
2025-03-12
Last updated
2025-10-03

Locations

1 site across 1 country: Netherlands

Source: ClinicalTrials.gov record NCT06871969. Inclusion in this directory is not an endorsement.