Trials / Completed
CompletedNCT06861959
Comparison Volume-controlled Ventilation, Pressure-controlled Volume-guaranteed Ventilation, and Pressure-controlled Ventilation During Gynecologic Laparoscopic Surgery in the Steep Trendelenburg Position
Comparison Volume-controlled Ventilation, Pressure-controlled Volume-guaranteed Ventilation, and Pressure-controlled Ventilation During Gynecologic Laparoscopic Surgery in the Steep Trendelenburg Position: A Randomized Controlled Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 60 (actual)
- Sponsor
- Dr. Lutfi Kirdar Kartal Training and Research Hospital · Other Government
- Sex
- Female
- Age
- 20 Years – 65 Years
- Healthy volunteers
- Not accepted
Summary
Objective: This study aimed to compare the effects of three different mechanical ventilation modes-Volume-Controlled Ventilation (VCV), Pressure-Controlled Ventilation (PCV), and Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG)-on pulmonary and hemodynamic variables during laparoscopic gynecologic surgery in the steep Trendelenburg position. The hypothesis was that PCV and PCV-VG would be superior to VCV in optimizing respiratory mechanics and improving oxygenation, particularly by reducing peak inspiratory pressure (Ppeak). Methods: Prospective, randomized, controlled clinical trial. Sixty ASA I-III patients aged 20-65 years undergoing elective laparoscopic gynecologic surgery in the steep Trendelenburg position were included (20 patients per ventilation group). Patients were randomized into VCV, PCV, and PCV-VG groups. Intraoperative ventilation was performed with a tidal volume of 8 mL/kg, PEEP of 5 cmH2O, and intra-abdominal pressure maintained at 12-14 mmHg. Data were collected at four time points: T1 (after induction, supine), T2 (30 min after CO2 insufflation, Trendelenburg), T3 (60 min after pneumoperitoneum), and T4 (after CO2 deflation, supine). Primary outcome: Ppeak comparison between groups. Secondary outcomes: Dynamic lung compliance (Cdyn), mean inspiratory pressure (Pmean), gas exchange, and hemodynamic parameters.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Device: Volume-Controlled Ventilation (VCV) | Tidal volume: 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4) |
| DEVICE | Device: Pressure-Controlled Ventilation (PCV) | Initial peak inspiratory pressure adjusted to deliver a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4) |
| DEVICE | Device: Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG) | Pressure-controlled mode with volume guarantee to maintain a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4) |
Timeline
- Start date
- 2021-01-01
- Primary completion
- 2021-08-01
- Completion
- 2021-09-01
- First posted
- 2025-03-06
- Last updated
- 2025-03-10
Locations
1 site across 1 country: Turkey (Türkiye)
Source: ClinicalTrials.gov record NCT06861959. Inclusion in this directory is not an endorsement.