Clinical Trials Directory

Trials / Completed

CompletedNCT06818461

Assessment of Corneal Biomechanical Properties Using Corvis ST Following LASIK, PRK, and CXL

Status
Completed
Phase
Study type
Observational
Enrollment
150 (actual)
Sponsor
Beni-Suef University · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Accepted

Summary

To evaluate corneal biomechanical changes using the Corvis ST in patients who have under-gone LASIK, PRK, and corneal cross-linking (CXL).

Detailed description

This observational study aims to evaluate corneal biomechanical changes in patients who have undergone LASIK, PRK, and corneal cross-linking (CXL) using the Corvis ST (Oculus). A total of 90 patients will be recruited from the ClearVision Laser Center database between January 2025 and December 2025. Participants will undergo non-contact biomechanical assessments at multiple postoperative time points to track corneal stability and elasticity over time. Data Collection \& Measurements Patient demographics, clinical history, and baseline preoperative data, including corneal thickness (pachymetry) and refractive status, will be collected. The Corvis ST will be used to measure key biomechanical parameters, such as Corneal Deformation Amplitude (CDA), Applanation Times (A1T \& A2T), Radius of Curvature at Highest Concavity (RHC), Stiffness Parameter (SP-A1), Integrated Radius (IR), and the Corvis Biomechanical Index (CBI). Measurement Protocol All measurements will be conducted in a controlled environment with stable room temperature and humidity. Patients will be properly aligned, and three consecutive measurements per eye will be taken to ensure repeatability. Data will be recorded at specific intervals: LASIK \& PRK: 1 month, 3 months, 6 months, and 12 months CXL: 1 month, 3 months, 6 months, 12 months, and 24 months Potential Benefits \& Risks The study aims to provide valuable insights into corneal biomechanical stability post-surgery, improving postoperative management and long-term visual outcomes. Risks are minimal, with only transient discomfort associated with the non-invasive Corvis ST measurements. This study will contribute to a better understanding of corneal biomechanics in refractive and therapeutic procedures, potentially guiding future surgical decisions and patient care strategies.

Conditions

Interventions

TypeNameDescription
OTHERCorvis St Before and after lasik, PRK, CXLcorneal biomechanics measurment using corvis St

Timeline

Start date
2023-09-01
Primary completion
2025-05-28
Completion
2025-10-31
First posted
2025-02-10
Last updated
2025-11-19

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT06818461. Inclusion in this directory is not an endorsement.