RecruitingNCT06818084

TRanscAtheter TreatMent of PurE Aortic Regurgitation With VitaFlow Liberty System

Transcatheter Treatment of Pure Aortic Regurgitation With VitaFlow Liberty System: a Prospective, Multicenter Study

Status
Recruiting
Phase
Phase 4
Study type
Interventional
Enrollment
120 (estimated)
Sponsor
Ruijin Hospital · Academic / Other
Sex
All
Age
60 Years
Healthy volunteers
Not accepted

Summary

This study is a prospective, multicenter, non-randomized controlled trial, planning to enroll 180 patients with pure native aortic regurgitation. On the basis of standardized medical therapy, patients will be assigned in a 1:1 ratio to undergo transfemoral transcatheter aortic valve replacement (TF-TAVR) . This prospective, multicenter trial aims to evaluate the safety and effectiveness of transfemoral TAVR using the VitaFlow™ self-expanding valve system compared to dedicated transcatheter devices in patients with PNAR. The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure. Secondary endpoints include procedure-related complications, long-term clinical events, patient functional status and quality of life, bioprosthetic valve imaging follow-up, echocardiographic parameters, and treatment costs. All endpoint definitions conform to the Valve Academic Research Consortium-3 (VARC-3) criteria

Detailed description

The purpose of this study is to evaluate the safety and efficacy of TF-TAVR for the treatment of isolated aortic regurgitation. The study will compare all-cause mortality, cardiovascular mortality, stroke, rehospitalization for heart failure, and renal failure requiring dialysis treatment at 12 months after TAVR. Additionally, the study will assess the incidence of hypoattenuated leaflet thickening (HALT) and reduced leaflet motion (RLM) via CTA, as well as the aortic valve root-prosthesis coaxiality. Changes and differences between groups in the following parameters will be evaluated using transthoracic echocardiography at 6 and 12 months after enrollment: left ventricular ejection fraction (Simpson method), left ventricular end-diastolic volume index (LVEDVi), left ventricular end-systolic volume index (LVESVi), left ventricular end-diastolic diameter (LVEDd), left ventricular end-systolic diameter (LVESd), estimated aortic valve orifice area, valvular regurgitation, and transvalvular pressure gradient compared with baseline. The study will also compare changes and differences between groups in the Minnesota Living with Heart Failure Questionnaire, Social Support Rating Scale (SSRS), International Physical Activity Questionnaire (IPAQ), and 6-minute walk test (6MWT) at 6 and 12 months after enrollment compared with baseline. Furthermore, the study will compare surgical costs, potential complication costs, and disease-related costs between the two groups.

Conditions

Interventions

TypeNameDescription
COMBINATION_PRODUCTVitaFlow+GDMTThe patient will undergo transcatheter aortic valve replacement on the basis of guideline-directed medical therapy with The VitaFlow™ system. The VitaFlow™ system (MicroPort®, Shanghai, China) was a novel TAVR system, which incorporates high-radial force and a double layer polyethylene terephthalate (PET) skirt to optimize frame geometry and minimize the risks of paravalvular leak (PVL). The VitaFlow™ transcatheter aortic valve is made of a self-expanding nitinol frame and tri-leaflet bovine pericardial valve.
COMBINATION_PRODUCTJ-Valve+GDMTThe patient will undergo transfemoral aortic valve replacement on the basis of guideline-directed medical therapy with The J-Valve system (Jie ChengMedical Technologies, Suzhou, China). The J-Valve system is a second-generation self-expand able device composed of a porcine bioprosthetic aortic valve and a transfemoral delivery sheath. The valve is supported by a self-expanding nitinol structure. The different valve sizes are 21, 23, 25, 27, 29 and 34 mm. Three U-shaped nitinol graspers were designed to surround the valve.

Timeline

Start date
2025-04-29
Primary completion
2027-11-30
Completion
2027-11-30
First posted
2025-02-10
Last updated
2026-01-30

Locations

4 sites across 1 country: China

Source: ClinicalTrials.gov record NCT06818084. Inclusion in this directory is not an endorsement.