Clinical Trials Directory

Trials / Recruiting

RecruitingNCT06797687

Mitral Valve Annulus Assessment, Multimodality Imaging

Mitral Valve Annulus Assessment, a Comparison Between 3D-TOE, CCT and Surgical Ring

Status
Recruiting
Phase
Study type
Observational
Enrollment
80 (estimated)
Sponsor
Fondazione Policlinico Universitario Agostino Gemelli IRCCS · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The success of mitral valve repair with annuloplasty depends on the repair technique and on the choice of a ring with appropriate dimensions related to mitral annulus. Intraoperatively, the choice of the prosthetic ring size is made by the surgeon using special gauges that are placed on the anterior mitral leaflet (having the trigons and commissures as anatomical findings), a method considered the gold standard for defining annulus size. However, it is performed in cardioplegia, without considering annulus shape and motion during cardiac cycle. Three-dimensional techniques are fundamental in evaluating mitral valve structure and its changes during cardiac cycle; three-dimensional transoesophageal echocardiography (3D-TOE) has been proven to be essential for the anatomo-functional characterization of mitral valve apparatus in patients undergoing surgically mitral valve repair. It also allows the measurement of quantitative parameters useful in determining the size of the annuloplasty ring, such as A2 scallop height, intertrigonal distance, intercommissural diameter and total annular perimeter size, that will support the surgeon's choice on the dimensions of the ring to be implanted. Cardiac computed tomography (CCT) plays a key role for device sizing in patients undergoing transcatheter mitral valve replacement; it provides isotropic sub-millimetre spatial resolution and it is the gold standard for geometric characterisation of the mitral valve and for assessment of the spatial relationship of mitral valve apparatus to adjacent anatomical structures. In patients undergoing mitral valve surgery it is foremost performed to exclude coronary artery disease, as stated by European Society of Cardiology (ESC) guidelines. Several studies have compared CCT with 3D-TOE in sizing the mitral valve apparatus: Shanks et al. have demonstrated a good correlation between the two techniques in measuring intercommissural diameter; Hirasawa et al. have demonstrated a good correlation in evaluating intertrigonal distance. Only one study has compared the measures of the annulus obtained by CCT with the prosthetic ring (Alkhadi et al.) and only for 9 patients the intercommissural diameter was compared to the prosthetic ring, obtaining a good correlation.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTCardiac computed tomographyMitral valve annulus measurements in the enrolled patients obtained will be obtained from: coronary CT scan, intraoperative transesophageal echocardiography and the ring surgically implanted during surgery.

Timeline

Start date
2025-03-15
Primary completion
2026-03-15
Completion
2026-05-15
First posted
2025-01-28
Last updated
2025-08-15

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT06797687. Inclusion in this directory is not an endorsement.