Clinical Trials Directory

Trials / Not Yet Recruiting

Not Yet RecruitingNCT06726512

Quantitative Margin Assessment Using High-resolution Positron Emission Tomography - Computed Tomograhy

Status
Not Yet Recruiting
Phase
N/A
Study type
Interventional
Enrollment
30 (estimated)
Sponsor
University Medical Center Groningen · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The primary endpoint is the assessment of the clinical value of a novel high-resolution mobile PET-CT scanner for intraoperative margin assessment in oral squamous cell carcinoma, soft tissue sarcoma and osteosarcoma surgery. The predicted margin status will be correlated with the margin status determined with histopathology.

Detailed description

The ideal outcome in oncological surgery is resection of all tumor tissue with a margin of healthy tissue. However, positive surgical margins (PSMs) occur in up to 35% of the cases, depending on tumor type. The final margin status is only available five to seven days after surgery so that in case of a PSM, intensive adjuvant radiotherapy or chemotherapy is necessary. Despite adjuvant treatment, patients still have a significantly reduced overall survival. Therefore, the intraoperative identification of PSMs is paramount to enable surgical corrections and obtain a complete resection. The investigators propose a dedicated intraoperative high-resolution PET-CT (positron emission tomography - computed tomography) imaging system for margin assessment of the excised specimen. The proposed specimen imaging system would combine the proven functional imaging capabilities of PET with the anatomical imaging info of CT, providing multi-modal information to determine whether tumor cells are present at the excision edges of the specimen. The tomographic images obtained can precisely demonstrate tumor extension along the x, y, and z axis, and the PET signal is not distorted by bone tissue. PET is the most sensitive medical imaging modality capable of detecting the picomolar concentrations of radiotracer, allowing to assess the presence of tumor cells within the specimen margins with high precision. Current standard PET-CT scanners have a spatial resolution between 3mm and 6mm, which is insufficient to accurately assess the excision margins of tumors. A specimen imaging system ideally should have a sub-millimeter resolution. The specimen PET system which will be used in this study is capable of this. The potential of intraoperative PET-CT has been shown in several tumor types, enabling the intraoperative identification of PSMs in prostatectomy and lumpectomy specimens.

Conditions

Interventions

TypeNameDescription
DEVICEXEOS AURA 10Surgery is performed according to standard of care. Directly after surgery, the surgical specimen is taken outside the operation theatre in a dedicated imaging room at the Department of Nuclear Medicine where high-resolution PET-CT imaging of the surgical specimen is performed.

Timeline

Start date
2025-01-01
Primary completion
2025-10-01
Completion
2026-04-01
First posted
2024-12-10
Last updated
2024-12-10

Locations

1 site across 1 country: Netherlands

Source: ClinicalTrials.gov record NCT06726512. Inclusion in this directory is not an endorsement.