Summary
The aim of the study is to measure the validity and reliability of the StUD test in patients with TKA. Forty-seven patients with primary TKA included in this study. The test-retest reliability of the StUD test was measured with 1-hour interval. Validity was assessed that the 30s Chair Stand Test (30sCS), the Hospital for Special Surgery score (HSS) and Short Form-12 Quality Life Questionnaire (SF-12) were used as comparator instruments.
Detailed description
The study was designed as test-retest research. This study was approved by the ethics committee of Dokuz Eylul University, Izmir, Turkey. This study was conducted between 2021 and 2022 at the Dokuz Eylul University Hospital Orthopedics Department, Izmir, Turkey. Informed consent was obtained from all participants in accordance with the Declaration of Helsinki. Sample Size The NCSS Trial and PASS 14 software (NCSS, LLC, Kaysville, Utah USA) was used to conduct the sample size. Power of 0.8 and an alpha level of 0.05 were used. Previous research on StUD in patients with knee Osteoarthritis was noted good test-retest reliability (ICC= 0.87) (G. P. L. Almeida et al., 2021). The test-retest reliability of the current study was thus hypothesized to be excellent. Assuming a %10 attrition rate, a null reliability with ICC=0.75 and expected reliability with ICC=0.90, 47 subjects would be needed. Participant Forty-seven patients with primary TKA who were operated on by the same surgeon using the paramedian approach were contacted by phone and volunteered to participate in this study. Patients with primary TKA who are at least six months post-surgery were included. Patients were selected and invited to the study by the surgeon and physiotherapist. Statistical Analysis All data were analyzed using the IBM SPSS Statistics (Version 23.0) software. The Kolmogorov-Smirnov/Shapiro-Wilk tests were used for the determination of the normal distribution. The difference between the pain levels before and after the trials was compared using the Paired Samples T test. The level of significance was determined p \< .05. The correlations between the StUD and 30 CST, HSS, PCS12, and MCS12 were calculated to determine convergent validity. The convergent validity was analyzed based on the Spearman's correlation and was interpreted as follows: 0-0.09 = no correlation; 0.1-0.39 = weak correlation; 0.4-0.59 = moderate correlation; 0.7-0.89 = strong correlation; and 0.9-1 = perfect correlation. Paired samples' t test was used for comparing the difference between the first and second trials of StUD test. The intraclass correlation coefficient (ICC2,1) was used assess the test-retest reliability. The ICC values were interpreted as follows: poor, \<0.5; moderate, 0.5-0.75; good, 0.75-0.9; excellent reliability, \>0.9 (Koo \& Li, 2016). The standard error of measurement (SEM) was calculated as SD×√(1-ICC) , where SD is the pooled standard deviation from the first session. Minimal detectable change (MDC) was calculated at a 95% confidence level (MDC95). MDC95 was calculated according to following formula: MDC95=SEM×1.95×√2. All data were analyzed using the IBM SPSS Statistics (Version 23.0) software
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | Step Up and Down Test | Step Up and Down Test In the StUD test, the patient completes maximum number of step-up-down repetitions in 15 seconds. Starting from a standing position, the participant took a full step up, leading with the test leg, then the non-testing leg, until both knees were fully extended and both hips were at least in neutral extension. In order to stress the testing limb concentrically and eccentrically, the participant stepped off the step first with the non-testing limb, then the testing limb. The patient was asked to repeat for 15 seconds as quickly as possible. The physical therapist stood to the side of the step for safety and so that he/she could observe the technique and ensure that the participant came to a full step up and down during the test. |
Timeline
- Start date
- 2021-02-01
- Primary completion
- 2021-05-15
- Completion
- 2021-05-15
- First posted
- 2024-04-03
- Last updated
- 2024-04-03
Locations
1 site across 1 country: Turkey (Türkiye)
Source: ClinicalTrials.gov record NCT06344182. Inclusion in this directory is not an endorsement.