Clinical Trials Directory

Trials / Unknown

UnknownNCT06175429

Prognostic Value of Exhaled Isoprene Levels for Morbidity and Functional Outcome in Cardiosurgical Patients

Prognostic Value of Exhaled Isoprene Levels for Morbidity and Functional Outcome in Cardiosurgical Patients - A Single Center Prospective Observational Cohort Study

Status
Unknown
Phase
Study type
Observational
Enrollment
66 (estimated)
Sponsor
University of Rostock · Academic / Other
Sex
All
Age
65 Years
Healthy volunteers
Not accepted

Summary

The perioperative preservation of functionality and quality of life plays an increasingly important role in older physically limited and frail patients undergoing cardiac surgery. Hereby, impairments of the skeletal muscle system integrity often contributes to a reduced physical performance. Early identification of these high-risk patients could help to initiate appropriate preventive and therapeutic measures. Volatile organic compounds (VOC) represent a non-invasive and real-time measurable approach for recording physiological and pathophysiological processes. Isoprene (2-methyl-1,3-butadiene) is one of the most abundantly exhaled VOCs and has recently been shown to originate from skeletal muscle metabolism. However, the prognostic value of isoprene as a volatile biomarker for skeletal muscle integrity, physical performance and functional outcome in patients undergoing cardiac surgery has not been evaluated before.

Detailed description

This is a single center prospective observational study evaluating exhaled isoprene as a perioperative volatile biomarker of skeletal muscle integrity, physical performance and functional outcome in cardiosurgical patients. All study participants will be assessed by comprehensive clinical examinations, laboratory testing, breath analysis and skeletal muscle ultrasound before, during as well as five and thirty days after surgery. Clinical assessments will be performed using established clinical scores and scales (e.g. the Short Physical Performance Battery and the Fried Frailty Index). Laboratory testing comprises a broad panel of blood-based biomarkers of skeletal muscle integrity and metabolism. The investigators hypothesize that: * perioperative exhaled isoprene levels correlate with postoperative measures of physical performance, functional outcome and morbidity * perioperative exhaled isoprene levels differ between patients with and without physical frailty * perioperative exhaled isoprene levels correlate with sonographic and laboratory parameters of skeletal muscle integrity

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTPhysical performance testingAssessment of physical performance using established clinical tests and scoring systems
DIAGNOSTIC_TESTBreath sampling and VOC analysisSampling of exhaled breath and using Proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOF) for VOC quantification.
DIAGNOSTIC_TESTMuscle ultrasoundQuantitative and qualitative assessment of different limb skeletal muscles using non-invasive ultrasound.
DIAGNOSTIC_TESTBlood-based biomarker analysisBlood sampling and assessment of different blood-based biomarkers of muscle integrity using Enzyme-linked Immunosorbent Assay (ELISA) and Electrochemiluminescence Immunoassay (ECLIA)

Timeline

Start date
2023-11-27
Primary completion
2025-10-01
Completion
2025-12-31
First posted
2023-12-18
Last updated
2023-12-18

Locations

1 site across 1 country: Germany

Source: ClinicalTrials.gov record NCT06175429. Inclusion in this directory is not an endorsement.