Clinical Trials Directory

Trials / Unknown

UnknownNCT06049706

Priming in Repetitive Transcranial Magnetic Stimulation in the Treatment of Obsessive Compulsive Disorder

Priming in Repetitive Transcranial Magnetic Stimulation (TMSr) in the Adjuvant Treatment of Obsessive Compulsive Disorder (OCD)

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
32 (estimated)
Sponsor
Suellen Andrade · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Accepted

Summary

Obsessive Compulsive Disorder results in high social impact, affecting quality of life and tending to a chronic course. A considerable proportion of patients, up tp 60%, remain with symptoms even thought treatment is administrated. Therefore, new therapeutic interventions are highly necessary. In this context, repetitive transcranial magnetic stimulation has been used for several psychiatric conditions, including OCD treatment. Moreover, many approaches of neuromodulation seem to reach a better result when used a priming stimulation. In an attemp to optimize particularities of the thecnique applied, this study aims to assess if a priming stimulation with rTMS might impact in a better outcome when compared with rTMS without previous stimulation.

Detailed description

This is a randomized, double-blind, sham-controlled clinical trial. Neuropsychological tests and a sociodemographic and clinical questionnaire will be used to assess and characterize the subjects. Participants captured by the Laboratory of Studies in Aging and Neuroscience at the Federal University of Paraíba will be divided into 02 groups, each with 16 patients, totaling 50 volunteers: Active - participants who will receive real priming stimulation; Sham - participants who will receive simulated priming stimulation. Participants entered through the eligibility criteria will be randomly allocated in a simple way, at a rate of 1:1. In the active priming, the parameters are: frequency of 6 Hz for 10 minutos, 80% do Motor Threshold (MT), 20 trains of 5 seconds, with intertrain interval of 25 seconds, a total f 600 stimulations. The group of innactive priming will have the same parameters, but without active atimulation. After this previous stimulation, all participants will receive the main stimulation: 10 sessions of rTMS, each lasting around 20 minutes, for 5 days a week, during two consecutive weeks. The target area will be the supplementary motor area. Primary outcome will be assessed by change in Yale-Brown Obsessive Compulsive Scale scores. As secondary outcomes, it will be used HAM-A for anxiety, HAM-D for depression, CGI-S for global clinical impression and SF-36 for quality of life.

Conditions

Interventions

TypeNameDescription
DEVICEActive PrimingIt will be applied an active priming stimulation in the supplementary motor area previously to the main stimulation to analyse if that will enhance the response to TMSr, compared to inactive priming. To apply intervention, it will be used Repetitive Transcranial Magnetic Stimulation Model MagPro R20 (MagVenture Brazil, country Brazil) and the butterfly coil MCF-B70 (MagVenture Brazil, country Brazil). Each session will last around 20 minutes, and it will be used a 1 Hz frequency, 1200 pulses/day, with 100% of Motor Threshold, once a day, 5 days a week, for two consecutive weeks. Active Priming group participants will be previously stimulated for 10 minutes (20 trains of 5 seconds with intertrain interval of 25 seconds), with 6Hz frequency over Supplementary Motor Area, receiving 80% of Motor Threshold, with a total of 600 stimulations.
DEVICESham PrimingSham Priming group participants will receive a placebo stimulation for ten minutes, with the same parameters and target area as the active group, they will hear the equipament noise and might feel any sensation in the scalp, but there won't be effective stimulation.

Timeline

Start date
2022-05-17
Primary completion
2023-09-01
Completion
2023-10-01
First posted
2023-09-22
Last updated
2023-09-22

Locations

1 site across 1 country: Brazil

Source: ClinicalTrials.gov record NCT06049706. Inclusion in this directory is not an endorsement.