CompletedNCT05690269

Oximeters and Skin Pigment: Impact of Skin Pigmentation on Accuracy of Pulse Oximetry

Impact of Skin Pigmentation on Accuracy of Pulse Oximetry

Status
Completed
Phase
Study type
Observational
Enrollment
232 (actual)
Sponsor
University of Cincinnati · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Finger pulse oximetry SpO2 is widely used to estimate arterial oxygen saturation SaO2. Current Spo2 targets do not take into consideration the many variables that affect that correlation in particular skin pigmentation. This study aims to evaluate different FDA approved pulse oximeters (Nonin co-pilot, massimo Radical 7, Philips-standard of care monitor, innovo premium iP900BP, nellcor PM1000N, Nano100) with SaO2 reference values obtained by an arterial blood gas in subjects with different skin pigments measured by a skin color scale as well as self-identification of race.

Detailed description

The oximeters that will be evaluated are nonin co-pilot, massimo Radical 7, Philips (standard care), Innovo Premium iP900BP, nellcor PM1000N and USA medical supply Nano100. The sensors used will be reusable digital sensors for all oximeters. Oximeters will have been placed on patients' fingers (3 fingers on each hand) during an initial phase of clinical stability. Due to the impact of the fingers used for SpO2 measurement and bias that might be caused by right hand versus left hand, oximeters will be randomized to different fingers and hands for each patient. Measurements will be made when the SpO2 with the usual oximeter is \<97% as recommended and in the absence of changes of the respiratory parameters in the last 10 minutes. A set of measures that will include all the oximeters tested will be used. Once the oximeters are installed, at least 2 minutes will run out to let the oximeters reach steady state. Then when a standard of care blood gas is obtained, measurements will be taken simultaneously to the drawing of a standard care arterial blood gas by a clinician in the ICU. While the clinician takes the arterial blood gas, a picture will be simultaneously taken of the SpO2 readings shown by each oximeter, in addition to taking vital signs, O2 flow or FiO2.

Conditions

Interventions

TypeNameDescription
DEVICESpO2 and SaO2 comparisonSeveral pulse oximeter will be place on patients fingers a few minutes before arterial blood gases. SpO2 will be recorded during that time and up to 10 minutes.

Timeline

Start date
2023-02-27
Primary completion
2025-03-31
Completion
2025-03-31
First posted
2023-01-19
Last updated
2025-05-31