Trials / Withdrawn
WithdrawnNCT05618093
Non-Invasive Measurement of Cardiac Output and Stroke Volume in PAH/CTEPH
Use of Non-invasive Measurement of Cardiac Output and Stroke Volume to Assess Risk and Response to Treatment in Patients With PAH or CTEPH
- Status
- Withdrawn
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 0 (actual)
- Sponsor
- University of California, Los Angeles · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) are severe clinical conditions that, despite advances in therapeutics over the past 20 years, lead to serious morbidity and mortality. Guidelines on the diagnosis and treatment of pulmonary hypertension (PH) recommend the use of a multiparametric risk stratification tool to determine severity of disease, which should guide initial therapy and therapy modulation. This multiparametric risk stratification schema includes objective assessment of exercise capacity, right ventricular function and hemodynamic parameters in order to classify patients into severity categories. Cardiac index (CI) and right atrial pressure (RAP), measured via right heart catheterization (RHC), are the hemodynamic parameters used in risk assessment of PH. Arguably, stroke volume index (SVI) is the most important hemodynamic parameter for assessment of PH severity and there is currently no validated method for noninvasive measurement of cardiac output (CO), CI or SVI. Currently, a major obstacle in the field is that hemodynamic measurements are not obtained on a regular basis in the risk assessment and therapy modulation of patients with PAH and CTEPH. If a noninvasive method of hemodynamic measurement could be correlated with other objective measurements of risk assessment, it could become an invaluable tool in therapy initiation and modulation in the ambulatory setting. This is a single center study to evaluate the use of non-invasive measurement of CO and stroke volume to assess risk and response to treatment in patients with PAH and non- operable CTEPH. We anticipate to enroll a total of 100 subjects at Ronald Reagan UCLA Medical Center. A maximum of 10 hour in total for the study including the consent process, pre-procedure care, RHC procedure, and follow up visit. The initial visit will be approximately 4 hours with the RHC procedure itself will only be 20 minutes. Each follow up visit will be 1.5 hour. Patients with known or suspected PAH or CTEPH will undergo a RHC as part of his or her standard of care. Three techniques of CO measurement will be performed sequentially at the time of the RHC. The device that will be used is the Edwards ClearSight system and EV1000 clinical platform, a device that measures NIBP. Patients will be followed over the period of 1 year every 3 months to obtain serial measurements for six-minute walk distance (6MWD), World Health Organization (WHO)/New York Heart Association Functional Class (FC), B-type natriuretic peptide (BNP) or N-terminal-pro hormone BNP (NT-proBNP), and non-invasive hemodynamic measurements. Additional visits will be scheduled to obtain the serial measurements one month prior and one month following if a patient is initiating or changing PH-specific therapy. As this is a study looking at the feasibility of non-invasive measurement of cardiac output and stroke volume for risk assessment and response to therapy in pulmonary arterial hypertension (PAH) or chronic thromboembolic pulmonary hypertension (CTEPH), study personnel performing the study procedures will not be blinded to the clinical diagnosis and the management of the subject.
Detailed description
This is a single center study to evaluate the use of non-invasive measurement of cardiac output and stroke volume to assess risk and response to treatment in patients with pulmonary arterial hypertension (PAH) and non- operable chronic thromboembolic pulmonary hypertension (CTEPH). We anticipate to enroll a total of 100 subjects at Ronald Reagan UCLA Medical Center. After informed consent is obtained, the following procedure will be performed: Patients with known or suspected pulmonary arterial hypertension (PAH) or chronic thromboembolic pulmonary hypertension (CTEPH) will undergo a right heart catheterization (RHC) as part of his or her standard of care. Three techniques of cardiac output (CO) measurement will be performed sequentially at the time of the RHC. The order of cardiac output testing will be randomized after informed consent is obtained and prior to the procedure. The operator performing the RHC procedure will be blinded to both the non-invasive blood pressure (NIBP) measurement and direct Fick cardiac output (CO) measurements while performing thermodilution cardiac output (CO) measurement. The device that will be used is the Edwards ClearSight system and EV1000 clinical platform, a device that measures non-invasive blood pressure (NIBP). Patients will be followed over the period of 1 year, up to every 3 months, to obtain serial measurements of six-minute walk distance (6MWD), World Health Organization (WHO)/New York Heart Association Functional Class (FC), and B-type natriuretic peptide (BNP) or N-terminal-pro hormone BNP (NT-proBNP) as part of standard of care. These serial measurements will be collected from the patient's medical record. Non-invasive hemodynamic measurements will be performed for research purposes. Additional visits will be scheduled to obtain the serial measurements one month prior and one month following if a patient is initiating or changing PH-specific therapy. As this is a study looking at the feasibility of non-invasive measurement of cardiac output and stroke volume for risk assessment and response to therapy in pulmonary arterial hypertension (PAH) or chronic thromboembolic pulmonary hypertension (CTEPH), study personnel performing the study procedures will not be blinded to the clinical diagnosis and the management of the subject.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Non-invasive hemodynamic measurements | A patient profile will be set up in the Edwards EV1000 clinical platform by inputting the patient's demographic information. One or two Edwards ClearSight finger cuffs will be placed on the index, middle, and/or ring finger on one hand of the patient. A pressure controller will be secured by a forearm strap where the finger cuffs will be connected to the pressure controller. The pressure controller will be connected to the Edwards EV1000 clinical platform monitor. A heart reference sensor (HRS) will be connected to the pressure controller, a finger cuff, and to the patient at heart level. The Edwards EV1000 clinical platform will calibrate the finger probes, then record measurements for 10-30 seconds. If two finger probes are available, measurements will alternate between fingers. |
Timeline
- Start date
- 2023-03-02
- Primary completion
- 2024-02-26
- Completion
- 2024-02-26
- First posted
- 2022-11-16
- Last updated
- 2026-02-03
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study