Clinical Trials Directory

Trials / Completed

CompletedNCT05606952

Color Doppler to Confirm Epidural Catheter Positioning in Parturient

Color Doppler to Confirm Epidural Catheter Positioning in Parturient, Would it Help

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
194 (actual)
Sponsor
Menoufia University · Academic / Other
Sex
Female
Age
18 Years – 45 Years
Healthy volunteers
Accepted

Summary

The aim of this study is to calculate the sensitivity and specificity of using color Doppler with pulsed wave Doppler to accurately detect the position of epidural catheter

Detailed description

patients will be divided into two groups Group (C) control these are the patients with BMI less than 35 and Group (O) for patients with BMI more than 35.All patients will be sitting to receive their epidural analgesia for labor pain. A 2.5 to 5 MHz curvilinear probe (Sonosite X-porte, Fujifilm industries) will be used to detect the desired level usually between L3-4 or L4-5. patients will be divided into two groups Group (C) control these are the patients with BMI less than 35 and Group (O) for patients with BMI more than 35. All patients will be sitting to receive their epidural analgesia for labor pain. A 2.5 to 5 MHz curvilinear probe (Sonosite X-porte, Fujifilm industries) will be used to detect the desired level usually between L3-4 or L4-5. Initially a parasagittal oblique interlaminar view will be obtained and by tilting it medially to visualize the laminae and interlaminar spaces. Starting by the sacral image, counting will start detecting the L5-S1, L4-L5 and L3-L4 levels. After marking the level another imaging in the transverse view will be attempted at the previous levels then the anesthetist will detect the posterior complex (ligamentum flavum, epidural space and dura) and anterior epidural complexes and according to the anesthetist preference a level will be This is followed by a test dose of 10 ml 0.125% bupivacaine and patient controlled epidural analgesia will be started by the following protocol (0.0625% bupivacaine) Smith Medical ASD,Inc. in intermittent dose (10 ml will be injected by the machine every 30 minutes.

Conditions

Interventions

TypeNameDescription
DEVICEColor Dopplercolor Doppler with pulsed wave Doppler to accurately detect the position of epidural catheter

Timeline

Start date
2022-12-01
Primary completion
2023-05-01
Completion
2023-11-10
First posted
2022-11-07
Last updated
2024-02-02

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT05606952. Inclusion in this directory is not an endorsement.