Clinical Trials Directory

Trials / Unknown

UnknownNCT05444621

Carotid Ultrasounds Measurements in Septic Shock

Carotid Ultrasounds Measurements for Assessment of Fluid Responsiveness in Septic Shock

Status
Unknown
Phase
Study type
Observational
Enrollment
72 (estimated)
Sponsor
Assiut University · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Not accepted

Summary

The aim of the study is to assess carotid ultrasounds measurements, namely corrected flow time (FTc), velocity time integral (VTI) and respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak), as a predictor of fluid responsiveness in septic shock patients.

Detailed description

Sepsis is life-threatening organ dysfunction caused by a dysregulated host response to infection . Early identification and appropriate management in the initial hours after the development of sepsis improve outcomes. For patients with sepsis-induced hypoperfusion or septic shock it is recommended to give IV crystalloid fluid within the first 3 hr of resuscitation . However, fluid responsiveness varies widely between cases. Determining the optimal amount of fluid to be administered remains a critical issue in clinical practice and research. Recent studies have shown that not every patient advantages from intravenous hydration, only 40% of hypotensive patients with sepsis benefit, and the others who do not respond are liable to develop pulmonary edema with high associated mortality . Studies have shown that aortic blood peak velocity had high sensitivity and specificity to predict fluid responsiveness, however, measurements of aortic blood flow velocity need a transesophageal ultrasound which is an invasive procedure . Measurement of left ventricular outflow tract velocity time integral (LVOTVTI), derived stroke volume (SV), and cardiac output reliably predicts fluid responsiveness in critically ill patients but it is difficult and dependent on operator and echo windows . There is a need to find a non-invasive accurate and easy method to assess fluid responsiveness in septic shock patients. Different Measurements of carotid artery flow have been suggested recently to predict fluid responsiveness. A promising measurements are corrected flow time (FTc), velocity time integral (VTI) and respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak).

Conditions

Interventions

TypeNameDescription
RADIATIONUltrasound and dopplerAll patients are then assessed by transthoracic echocardiography to measure Left ventricle and Right ventricle function and to assess LVOT-VTI and SV. Doppler Ultrasound assessment of carotid arteries to assess corrected flow time (FTc), velocity time integral (VTI) and respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak). The patient will be assessed pre- and post- passive leg raising (PLR) and after fluid challenge of 30 mL/Kg of IV crystalloid

Timeline

Start date
2022-07-01
Primary completion
2023-09-30
Completion
2024-10-31
First posted
2022-07-06
Last updated
2022-07-06

Source: ClinicalTrials.gov record NCT05444621. Inclusion in this directory is not an endorsement.