Long-term Safety and Performance of KiOmedine CM-Chitosan Supplementation in Advanced Symptomatic Knee Osteoarthritis

Safety and Performance of an Intra-articular Injection of KiOmedine CM-Chitosan in Patients With Advanced Symptomatic Knee Osteoarthritis: Single-blind Randomized Controlled Trial With a 12-month Follow-up Period.

Status
Unknown
Phase
Phase 4
Study type
Interventional
Enrollment
104 (actual)
Sponsor
Kiomed Pharma · Industry
Sex
All
Age
40 Years – 85 Years
Healthy volunteers
Not accepted

Summary

A single-blind randomized controlled design intended for the assessment of safety and performance of a single intra-articular injection of the IMD. In the study, 92 patients meeting eligibility criteria will be randomly assigned to two groups respectively of 46 subjects receiving a single injection of the IMD and 46 subjects receiving a single injection of Synvisc-One® (Hylan G-F 20) which is selected as comparator. Each patient will be blinded for the treatment he/she receives at the injection visit (single blinding). The patients will be followed for 12 months post-injection to understand long-term safety and performance effects. The study aims to evaluate the safety and performance of a single injection of KiOmedine® CM-Chitosan compared to the comparator device (Synvisc-One®) in patients with advanced symptomatic knee osteoarthritis. The non-inferiority hypothesis for the primary performance objective is that the percentage mean reduction in pain from baseline at 6 months in the KiOmedine® CM-Chitosan group is non-inferior to that of the comparator group considering a non-inferiority margin. If the hypothesis of non-inferiority is met, then superiority testing will be performed.

Conditions

Interventions

TypeNameDescription
DEVICEKiOmedine® CM-ChitosanKiOmedine® CM-Chitosan is a fluid implant intended for synovial fluid supplementation for the symptomatic treatment of osteoarthritis (OA). This Investigational Medical Device (IMD) is administered via intra-articular injection and is classified as a Class III Device under Council Directive 93/42/EEC (Annex IX, rule 8). A key component of the IMD is a soluble derivative of highly purified chitosan of non-animal origin, an exclusive natural linear glucosamine polysaccharide extracted from the edible white mushroom, Agaricus bisporus. KiOmedine® CM-Chitosan is sterile, non-pyrogenic, resorbable and composed of 2% (w:w) carboxymethyl chitosan (CM-chitosan).
DEVICESynvisc-One®Synvisc-One (Hylan G-F 20) is a sterile, nonpyrogenic, elastoviscous fluid containing Hylan A and Hylan B polymers produced from chicken combs. Hylans are derivatives of hyaluronan (sodium salt of hyaluronic acid) and consist of repeating disaccharide units of N-acetylglucosamine and sodium glucuronate. Hylan A has an average molecular weight of approximately 6,000,000 daltons and hylan B is a hydrated gel. Hylan G-F 20 contains Hylan A and Hylan B (8.0 mg ± 2.0 mg per ml) in buffered physiological sodium chloride solution (pH 7.2 ± 0.3) and is unique in that the hyaluronan is chemically crosslinked.

Timeline

Start date
2022-01-26
Primary completion
2023-08-20
Completion
2024-02-20
First posted
2022-01-31
Last updated
2023-03-08

Locations

1 site across 1 country: Belgium