Clinical Trials Directory

Trials / Completed

CompletedNCT05209204

Anterior Chamber Angle Examination in Angle Closure Suspect Patients

Status
Completed
Phase
Study type
Observational
Enrollment
40 (actual)
Sponsor
Minia University · Academic / Other
Sex
All
Age
40 Years – 70 Years
Healthy volunteers
Not accepted

Summary

The aim of this study is to detect PACG suspects using both AS OCT and Scheimpflug imaging.

Detailed description

Glaucoma is a form of progressive optic neuropathy and is one of the leading causes of preventable blindness worldwide. The average life span is increasing leading to more individuals developing glaucoma as well as having the disease longer, which makes early detection and management very important.\[1\] Glaucoma is characterized by loss of retinal ganglion cells (RGCs) recognized as optic nerve head (ONH) changes, corresponding visual field (VF) defects and retinal nerve fiber layer (RNFL) loss. At least 40% of RGCs are lost before the VFs show a defect, hence the emphasis on early diagnosis in the stage of glaucoma suspect.\[2\] There are two types of glaucoma suspect: Primary Open angle and primary angle closure suspect.(3) Primary angle-closure (PAC) suspects can be detected by the following: the trabecular meshwork can only be seen in 180º or less of anterior chamber angle (AC) by gonioscopy, the intraocular pressure(IOP) remains within normal limits and no structural damage to the optic nerve is present.\[4\] Time domain Optical coherence tomography (TD-OCT) was initially designed to image the posterior segment and retina, but its capability to generate cross-sectional images of internal biological structures without contacting the ocular surface was quickly adapted to visualize the anterior segment and cornea.\[5\]. Spectral domain anterior segment OCT (SD-OCT) technology allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Spectral-domain OCT(SD OCT) instruments working at 840 nm can reliably identify fine angle structures such as Schwalbe's line.(6) Scheimpflug imaging also offers non-contact imaging of the anterior segment. Although Scheimpflug photography cannot fully visualize the entire angle, the software available on the Pentacam system (Oculus Optikgeräte, Wetzlar, Germany) provides extrapolated measurements of the anterior chamber volume (ACV), which have shown promise in screening for narrow angles.(7)

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTASOCTAnterior segment imaging using RTVue XR 100 Avanti OCT platform (Optovue Inc.,Fairmont, CA).
DIAGNOSTIC_TESTPentacamAnterior segment imaging using Oculus Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany).

Timeline

Start date
2019-04-01
Primary completion
2019-12-01
Completion
2020-01-01
First posted
2022-01-26
Last updated
2022-01-26

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT05209204. Inclusion in this directory is not an endorsement.