Summary

In keratoconic eyes, the corneal epithelium shows a localized thinning over the cone that is surrounded by an annulus of epithelial thickening. It has been postulated that epithelial thickness mapping can be a sensitive tool for the keratoconus diagnosis. In keratoconus screening the 5 mm diameter of the corneal centrum may be sufficient while studies have shown that the cone apex is located in this area. Aim of this study is to assess agreement and repeatability of epithelial thickness measurements using two optical coherence tomography devices in healthy and keratoconus corneas. Secondary objective is to evaluate the differences between healthy and keratoconus eyes using epithelial thickness map data. This is a prospective monocentric study that includes patients divided into two groups: patients with keratoconus and a control group formed out of patients without corneal pathologies. For each patient only one eye will be included and corneal measurements will be performed, focused on the corneal epithelium thickness.

Detailed description

In total 50 eyes of 50 patients will be included, divided into two groups: study group comprised of 20 eyes with diagnosed keratoconus and a control group formed out of 30 healthy eyes. Patients included in the study will be measured with the corneal acquisition mode, also allowing for epithelium thickness data, on each device without pupil dilatation. After each measurement patients will be asked to blink in order to allow adequate tear-film recovery. Each patient will be measured three times with both devices. Only one visit will be necessary. The order in which the measurements will be performed (Anterion or MS-39) will be randomised using randomised.org. The corneal epithelial thickness will be measured as the distance between the air-tear and the epithelium-Bowman interfaces. Main outcome variable: \- Mean differences in central corneal epithelial thickness between the devices investigated (+ limits of agreement (1.96xSD) between the investigated devices) Secondary outcome variables: * Repeatability coefficient (within subject standard deviation - SD) and coefficient of variation of the two devices * Comparison in epithelial thickness between normal and keratoconus eyes * Sensitivity and specificity of swept-source OCT device in keratoconus diagnosis

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTCorneal epithelial thickness measurementsCorneal epithelial thickness measurements using two optical coherence tomography devices in healthy and keratoconus corneas.

Timeline

Start date
2020-10-15
Primary completion
2021-02-01
Completion
2021-03-01
First posted
2020-10-08
Last updated
2020-10-12

Locations

1 site across 1 country: Austria

Source: ClinicalTrials.gov record NCT04578184. Inclusion in this directory is not an endorsement.