Clinical Trials Directory

Trials / Unknown

UnknownNCT04534192

Investigating the Safety and Efficacy of the Treatment With the Non-compliant Jade Balloon in TASC C and D Athero-occlusive Infra-inguinal Disease in Patients With Chronic Limb Threatening Limb Ischemia From SingaporE

Physician Initiated, Prospective, Non-randomized Single-centre, Single-arm Trial, Investigating the Safety and Efficacy of the Treatment With the Non-compliant Jade Balloon in TASC C and D Athero-occlusive Infra-inguinal Disease in Patients With Chronic Limb Threatening Limb Ischemia From SingaporE (PINNACLE)

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
Singapore General Hospital · Academic / Other
Sex
All
Age
40 Years
Healthy volunteers
Not accepted

Summary

The objective of this clinical study is to evaluate the 6-month safety and performance outcome of the non-compliant high pressure JADE balloon for the treatment of infrainguinal stenotic occlusive or stenotic TASC C \& D lesions in patients with chronic limb threatening ischemia.

Detailed description

Pulsatile straight line blood flow to the foot is required to aid wound healing in the setting of chronic limb threatening ischaemia (CLTI). Patients with CLTI usually present with infra-popliteal arterial occlusions and endovascular therapies to restore blood flow are often preferred considering their inherently less invasive nature and because of multiple patient background comorbidities or absence of a suitable vein conduit in these patients. Below The Knee (BTK) plain balloon angioplasty (POBA) remains the only viable "standard of care" in the management of long "Real World" BTK Lesions. However tibial angioplasty is plagued by high rate of re-occlusion/stenosis because of barotrauma caused by the intra-arterial ballooning and subsequent development of neointimal hyperplasia. Devices coated with paclitaxel have been used successfully to limit restenosis by inhibiting the biologic pathway that leads to intimal hyperplasia. However, a recent formal systematic review and study-level meta-analysis of randomized controlled trials investigating treatment of the infra-popliteal arteries with paclitaxel-coated balloons compared with conventional balloon angioplasty for critical limb ischemia (CLI) was recently published showing amputation-free survival was significantly worse in use of paclitaxel coated balloons compared to plain angioplasty. Furthermore current poor patency seen in BTK angioplasty is likely contributed in part by small vessel size and poor luminal gain after standard semi-compliant POBA. Vessel Preparation and Optimising POBA with High Pressure, Non-Compliant balloons may help achieve Luminal Gain for rapid and sustained flow for wound healing. The objective of this clinical study is to evaluate the 6-month safety and performance outcome of the non-compliant high pressure JADE balloon for the treatment of infrainguinal stenotic occlusive or stenotic TASC C \& D lesions in patients with chronic limb threatening ischemia.

Conditions

Interventions

TypeNameDescription
DEVICEJADE BalloonSuitable TASC C and D lesions will be treated with non-compliant high pressure JADE balloon.

Timeline

Start date
2020-08-01
Primary completion
2022-03-01
Completion
2022-08-01
First posted
2020-09-01
Last updated
2020-11-02

Locations

1 site across 1 country: Singapore

Source: ClinicalTrials.gov record NCT04534192. Inclusion in this directory is not an endorsement.