Summary
Assessment of fluid responsiveness (FR) is to detect whether patient could benefit from fluid therapy. Mini fluid challenge has been widely used in clinical practice to prevent patients from volume overload. In clinical practice, 100 mL or 250 mL have been used most frequently and FR was defined as an increase in CO greater than 10% as much as the changes in CO after infusion of 500 mL. While using a half of volume infusion and assessed by the traditional standard of FR, this might misclassify more patients as nonresponders. In that it is imperative to test the predictive ability of mini fluid and find out the threshold of cutoff value. Meanwhile, in almost mini-FC, cardiac output were measured by echocardiography(VTi) and pulse contour,None of the studies conducted cardiac output (CO)measurement by gold standard method of thermodilution by pulmonary artery catheter (PAC). The correlation between new generated CO measurements and PAC varies in different studies as well. It is imperative to investigate the reliability of mini-FC to predicting fluid responsiveness(FR).The investigator's study is to detect the predictive minimal volume using thermodilution by PAC in septic shock patient.
Detailed description
Fluid therapy is the cornerstone of septic resuscitation. In recent decade, a restrictive fluid strategy has been applied to shock resuscitation for fewer complications and shorter hospital stays compared with a liberal fluid strategy. Therefore, it is a reasonable step to assess the patient's response to fluid infusion to avoid excessive fluid administration.Mini-fluid challenge allows the selection of fluid responders by inducible changes of hemodynamic parameters after changing the preload gaining popularity. The mini fluid challenge was firstly described by Muller et al. in 2011. They found an infusion of 100 mL colloid over 1 minute and the assessment by cardiac output using velocity time integral (VTi) at the aortic outflow tract could predict fluid responsiveness (FR). Since then, a total of seven investigations have been published. Although a mini-fluid challenge may help the decision-making process of fluid management, the investigation results differed from each other, especially in minimal volume and cut off value of hemodynamic parameters change. Meanwhile, we noticed that when measuring CO, the method of thermodilution by pulmonary artery catheter (PAC), which is the gold standard of CO measurement, was not used in these studies. Furthermore, the majority participants of the studies were perioperative patients in a stable hemodynamic state.Therefore, there are two question needed to be answered:what is the minimal infusion volume in effectively predicting fluid responsiveness, and whether mini-volume can perform a real change in septic shock patients. Thus, it is necessary to explore the minimal volume in fluid challenge by PAC and test its reliability in detecting responders (R) and nonresponders (NR).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | 4% gelatin | Pulmonary artery catheter insertion is prepared before fluid challenge. Baseline hemodynamic value and each time after 5 sequential intravenous boluses of 100 mL colloid are recorded. |
Timeline
- Start date
- 2019-07-01
- Primary completion
- 2020-08-01
- Completion
- 2022-09-01
- First posted
- 2020-08-17
- Last updated
- 2020-09-03
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT04515511. Inclusion in this directory is not an endorsement.