Trials / Unknown
UnknownNCT04083690
Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 120 (estimated)
- Sponsor
- Allina Health System · Academic / Other
- Sex
- All
- Age
- 18 Years – 100 Years
- Healthy volunteers
- Not accepted
Summary
Cardiac resynchronization therapy (CRT), or atrial-synchronized biventricular (BiV) pacing, is an FDA-approved device therapy option for heart failure (HF) patients with reduced left ventricular ejection fraction and electrical dyssynchrony. A traditional CRT device has pacing leads implanted within the right atrium (RA), the right ventricle (RV), and within a coronary vein overlying the lateral or posterior left ventricle (LV). Within the past decade, various multi-center randomized controlled trials have reported improved quality of life, aerobic exercise capacity, LV systolic function and structure, as well as decreased hospitalization rates and mortality among patients with HF. Despite improvements in CRT technology with multipoint pacing, quadripolar leads, and adaptive pacing algorithms, approximately 30% of patients do not clinically benefit and are considered non-responders. This study looks to optimize new CRT device recipients using information obtained from standard ECG machines.
Detailed description
This is a prospective, randomized study designed to evaluate if CRT device optimization, guided by electrocardiography, improves echocardiographic and clinical outcomes among HF patients with a CRT device implanted for standard indications. All patients will have measurement of electrocardiograms at a range of device settings. Patients will be randomized in a 1:1 ratio to either the active comparator arm (standard CRT programming), or the experimental arm (CRT device programmed by the information obtained by ECGs). Standard CRT programming used in this study is simultaneous biventricular (BiV) pacing with a fixed atrioventricular delay. At 6 months, control patients who were initially randomized to standard programming will have programming changed based on the ECG optimization information. Patients will be blinded to randomization. Change of LV size and function will be performed prior to randomization, and again \~6 and \~12 months following CRT implant in both subgroups.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Reprogramming of CRT Device Settings to Optimal Electrical Synchrony | Reprogramming of CRT device to maximize the benefit based on the ECG CRT optimization information. |
Timeline
- Start date
- 2019-10-11
- Primary completion
- 2023-10-01
- Completion
- 2024-10-01
- First posted
- 2019-09-10
- Last updated
- 2022-06-09
Locations
2 sites across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT04083690. Inclusion in this directory is not an endorsement.