Trials / Active Not Recruiting
Active Not RecruitingNCT03735667
ACURATE IDE: Safety and Effectiveness Study of ACURATE Valve for Transcatheter Aortic Valve Replacement
ACURATE IDE: Transcatheter Replacement of Stenotic Aortic Valve Through Implantation of ACURATE in Subjects InDicatEd for TAVR
- Status
- Active Not Recruiting
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 1,948 (actual)
- Sponsor
- Boston Scientific Corporation · Industry
- Sex
- All
- Age
- —
- Healthy volunteers
- Not accepted
Summary
To evaluate safety and effectiveness of the ACURATE Transfemoral Aortic Valve System for transcatheter aortic valve replacement (TAVR) in subjects with severe native aortic stenosis who are indicated for TAVR. As of 28-May-2025, Boston Scientific Corporation (BSC) announced the voluntary global discontinuation of the ACURATE product platform, including both the ACURATE neo2 and ACURATE Prime Aortic Valve Systems. BSC will no longer pursue regulatory approval for the device in the U.S. or other unapproved geographies.
Detailed description
Subjects will be enrolled at up to 85 centers in the United States, Canada, Europe, and Australia. There will be up to 2,820 subjects in ACURATE IDE. The ACURATE IDE study cohorts include the following. * Main Randomized Cohort: A prospective, multicenter, 1:1 randomized controlled trial (RCT; ACURATE versus a commercially available balloon-expandable SAPIEN 3™ Transcatheter Heart Valve or future iteration \[SAPIEN 3; Edwards Lifesciences LLC, Irvine, CA, USA\] or a commercially available self-expanding CoreValve® Transcatheter Aortic Valve Replacement System, CoreValve® Evolut™ R Recapturable TAVR System, EVOLUT™ PRO System, or future iteration \[CoreValve; Medtronic, Inc., Dublin, Ireland\]). There will be up to 1,500 subjects in the RCT. * Roll-In Cohort: A non-randomized roll-in phase with the test device. Centers that do not have implantation experience with the ACURATE neo™ Aortic Bioprosthesis (transfemoral delivery; Boston Scientific Corporation, Marlborough, MA, USA) will perform at least 2 roll-in cases before commencing treatment in the randomized cohort. Centers with prior experience with ACURATE are not required to do roll-in cases. Data from roll-in subjects will be summarized separately from the randomized cohort and will not be included in the primary endpoint analysis. * 4D CT Imaging Substudy: Selected centers with the ability to perform high quality 4D computer tomography (CT) scans will include subjects in a 4D CT Imaging Substudy to assess the prevalence of reduced leaflet mobility and hypoattenuated leaflet thickening (HALT) and the relationship, if any, to clinical events. Subjects will be randomized to test (ACURATE) and control device. * ACURATE Prime™ XL Nested Registry: A non-randomized, nested registry cohort of subjects who will receive the ACURATE Prime™ Transfemoral Aortic Valve System XL (ACURATE Prime XL Nested Registry). Participating centers will be a subset of United States centers that have enrolled subjects in ACURATE IDE. Data from subjects in this nested registry will be summarized separately from the randomized and roll-in cohorts. * ACURATE Extended Durability Study: An additional 1:1 randomized study (ACURATE versus a commercially available balloon-expandable SAPIEN 3™ Transcatheter Heart Valve or future iteration \[SAPIEN 3; Edwards Lifesciences LLC, Irvine, CA, USA\] or a commercially available self-expanding CoreValve® Transcatheter Aortic Valve Replacement System, CoreValve® Evolut™ R Recapturable TAVR System, EVOLUT™ PRO System, or future iteration \[CoreValve; Medtronic, Inc., Dublin, Ireland\]) including only subjects considered to be at low surgical risk. Subjects will receive ACURATE neo2 (S, M, or L valve sizes) or ACURATE Prime XL. Data from subjects in the Extended Durability Study will be summarized separately from other cohorts. * ACURATE Continued Access Study (CAS): An additional cohort of subjects receiving ACURATE neo2 (S, M, and L valve sizes) or ACURATE Prime XL. Data from subjects in the ACURATE CAS will be summarized separately from other cohorts and will be used to further assess performance and safety. Follow-up * Subjects implanted with a test device will be assessed at baseline, peri- and post-procedure, at discharge or 7 days post-procedure (whichever comes first), 30 days, 6 months, 1 year, and then annually for 5 years post-procedure. * Subjects implanted with a control device will be assessed at baseline, peri- and post-procedure, at discharge or 7 days post procedure (whichever comes first), 30 days, 6 months, and 1 year post procedure. Per protocol, no additional follow-up is required beyond this period, and standard of care practices will apply. * Some subjects may have completed additional annual follow-up visits based on requirements outlined in earlier versions of the protocol. * Subjects who are enrolled but not implanted with a test or control device at the time of the procedure will be followed for safety through 1 year.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | ACURATE neo2™ Transfemoral TAVR System | ACURATE neo2™ Transfemoral TAVR system: Support frame made of nitinol, supra-annular processed tri-leaflet porcine pericardial valve and an outer skirt to limit paravalvular regurgitation (manufactured by Boston Scientific Corporation, Marlborough, MA, USA). |
| DEVICE | Medtronic CoreValve TAVR System | Medtronic CoreValve Evolut R or Evolut PRO Transcatheter Aortic Valve Replacement (TAVR) System (or any future Corevalve iterations): The support frame is manufactured from nitinol, which has multilevel, self-expanding properties and is radiopaque. The bioprosthesis is manufactured by suturing valve leaflets and a skirt from porcine pericardium into a tri-leaflet configuration (manufactured by Medtronic CoreValve LLC, Santa Ana, USA). |
| DEVICE | Edwards SAPIEN 3 TAVR System | Edwards SAPIEN 3 TAVR system (or any future SAPIEN iterations): balloon-expandable transcatheter aortic bioprosthesis, support frame made of cobalt-chromium, three leaflets constructed of processed bovine pericardial tissue and an outer polyethylene terephthalate (PET) sealing cuff to mitigate paravalvular regurgitation (manufactured by Edwards Lifesciences, Inc., Irvine, California, USA) |
| DEVICE | ACURATE Prime™ Transfemoral TAVR System XL | ACURATE Prime™ Transfemoral TAVR system: Support frame made of nitinol, supra-annular processed tri-leaflet porcine pericardial valve and an outer skirt to limit paravalvular regurgitation (manufactured by Boston Scientific Corporation, Marlborough, MA, USA). |
Timeline
- Start date
- 2019-06-10
- Primary completion
- 2024-06-14
- Completion
- 2029-09-01
- First posted
- 2018-11-08
- Last updated
- 2025-12-10
- Results posted
- 2025-04-27
Locations
75 sites across 2 countries: United States, Canada
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT03735667. Inclusion in this directory is not an endorsement.