Ventilator Hyperinflation and Hemodynamics
Hemodynamic Repercussions of Ventilator Hyperinflation Using Volume-controlled Ventilation: a Randomized Controlled Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 17 (actual)
- Sponsor
- Centro Universitário Augusto Motta · Academic / Other
- Sex
- All
- Age
- 18 Years – 90 Years
- Healthy volunteers
- Not accepted
Summary
Ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode. In a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause) and a control intervention. Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions.
Detailed description
Background: ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode. Methods: in a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause of 2 seconds) and a control intervention. For the VHI interventions, the inspiratory flow will be set at 20 Lpm, and tidal volume will be increased until a peak pressure of 40cmH2O is achieved. During the control intervention, the patients will remain in volume-control ventilation with an inspiratory flow = 60Lpm and tidal volume = 6mL/IBW. The interval between interventions (washout) will be of 10 minutes or more, according to the time needed to recover the cardiac index to baseline values (maximum difference of 10%). Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions by using impedance cardiography.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Baseline Mechanical Ventilation | The subjects will be kept in Volume Control Continuous Mandatory Ventilation (VC-CMV). |
| DEVICE | VHI With Inspiratory Pause | Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory pause. |
| DEVICE | VHI Without Inspiratory Pause | Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) without an inspiratory pause. |
Timeline
- Start date
- 2017-11-05
- Primary completion
- 2018-09-20
- Completion
- 2018-09-30
- First posted
- 2018-06-15
- Last updated
- 2020-08-14
Locations
1 site across 1 country: Brazil
Source: ClinicalTrials.gov record NCT03557645. Inclusion in this directory is not an endorsement.