Clinical Trials Directory

Trials / Completed

CompletedNCT03557645

Ventilator Hyperinflation and Hemodynamics

Hemodynamic Repercussions of Ventilator Hyperinflation Using Volume-controlled Ventilation: a Randomized Controlled Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
17 (actual)
Sponsor
Centro Universitário Augusto Motta · Academic / Other
Sex
All
Age
18 Years – 90 Years
Healthy volunteers
Not accepted

Summary

Ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode. In a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause) and a control intervention. Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions.

Detailed description

Background: ventilator hyperinflation (VHI) has been shown to be effective in improving respiratory mechanics, secretion removal, and gas exchange in mechanically ventilated patients; however, the literature is scarce concerning its safety and adverse effects. Thus, the aim of this study is to compare the hemodynamic repercussions of VHI in volume-controlled mode. Methods: in a randomized, controlled and crossover design, 24 mechanically ventilated patients will undergo 2 modes of ventilator hyperinflation (with and without an inspiratory pause of 2 seconds) and a control intervention. For the VHI interventions, the inspiratory flow will be set at 20 Lpm, and tidal volume will be increased until a peak pressure of 40cmH2O is achieved. During the control intervention, the patients will remain in volume-control ventilation with an inspiratory flow = 60Lpm and tidal volume = 6mL/IBW. The interval between interventions (washout) will be of 10 minutes or more, according to the time needed to recover the cardiac index to baseline values (maximum difference of 10%). Cardiac output, cardiac index, mean arterial pressure, pulmonary vascular resistance, systolic volume and other hemodynamic variables will be recorded during the interventions by using impedance cardiography.

Conditions

Interventions

TypeNameDescription
DEVICEBaseline Mechanical VentilationThe subjects will be kept in Volume Control Continuous Mandatory Ventilation (VC-CMV).
DEVICEVHI With Inspiratory PauseApplication of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) with an inspiratory pause.
DEVICEVHI Without Inspiratory PauseApplication of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV) without an inspiratory pause.

Timeline

Start date
2017-11-05
Primary completion
2018-09-20
Completion
2018-09-30
First posted
2018-06-15
Last updated
2020-08-14

Locations

1 site across 1 country: Brazil

Source: ClinicalTrials.gov record NCT03557645. Inclusion in this directory is not an endorsement.