Clinical Trials Directory

Trials / Unknown

UnknownNCT03449602

Minirigid Versus Conventional Rigid Thoracoscopy in Undiagnosed Pleural Effusions

A Randomized Trial Comparing the Diagnostic Sensitivity and Safety of Mini-thoracoscopy Versus Conventional Rigid Thoracoscopy in Undiagnosed Pleural Effusions

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
100 (estimated)
Sponsor
Post Graduate Institute of Medical Education and Research, Chandigarh · Academic / Other
Sex
All
Age
15 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Consecutive patients who are planned to undergo a medical thoracoscopy for obtaining pleural biopsies will be enrolled in the study. One hundred subjects will be randomized in 1:1 ratio to undergo thoracoscopy to the following groups: Group A (mini-thoracoscopy) Group B (Conventional rigid thoracoscopy) Primary outcome: (a) diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions

Detailed description

A significant proportion of patients with pleural effusions remain undiagnosed after performance of diagnostic procedures including cytological and microbiologic analysis of the pleural fluid and closed pleural biopsies. In this study, the investigators plan to compare the yield and safety of mini-thoracoscopy and conventional rigid thoracoscopy with the larger diameter scope. This is a prospective study that will be conducted at the Thoracic Endoscopy Suite of the Department of Pulmonary Medicine, PGIMER, Chandigarh. Consecutive patients who are planned to undergo a medical thoracoscopy for obtaining pleural biopsies will be enrolled in the study One hundred subjects will be randomized in 1:1 ratio to undergo thoracoscopy. The randomization sequence will be generated using a computer (in blocks of 10), and the allocation will be placed in opaque sealed envelopes. The patients will be randomized to the following groups: Group A (mini-thoracoscopy): The mini-thoracoscope manufactured by Richard Wolf GmbH, Knettligen, Germany will be used. It has an outer diameter of 5.5 mm and a working channel diameter of 3.5 mm. Group B (Conventional rigid thoracoscopy): The rigid thoracoscope manufactured by Richard Wolf GmbH, Knettligen, Germany will be used that has an outer diameter of 10 mm and channel internal diameter of 5 mm. Primary outcome: (a) diagnostic sensitivity of mini-thoracoscopy and conventional rigid thoracoscopy in the diagnosis of exudative pleural effusions.

Conditions

Interventions

TypeNameDescription
DEVICEMini-thoracoscopyThoracoscopic pleural biopsy with the mini-thoracoscope
DEVICEConventional rigid thoraoscopyThoracoscopic pleural biopsy with the conventional rigid thoraoscope

Timeline

Start date
2018-03-01
Primary completion
2023-09-30
Completion
2023-09-30
First posted
2018-02-28
Last updated
2023-03-29

Locations

1 site across 1 country: India

Source: ClinicalTrials.gov record NCT03449602. Inclusion in this directory is not an endorsement.