Trials / Completed
CompletedNCT03366935
Combined Implementation of Dural Puncture Epidural and Programmed Intermittent Epidural Bolus for Labor Analgesia
Combined Implementation of Dural Puncture Epidural Technique and Programmed Intermittent Epidural Bolus for Labor Analgesia
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 120 (actual)
- Sponsor
- Shanghai First Maternity and Infant Hospital · Academic / Other
- Sex
- Female
- Age
- 20 Years – 40 Years
- Healthy volunteers
- Accepted
Summary
This study intends to carry out a prospective, randomized double-blind study to evaluate the safety and efficacy of the combined implementation of Dural puncture epidural (DPE) technique and Programmed intermittent epidural bolus (PIEB) for labor analgesia.
Detailed description
Epidural (EPL) technique is the standard technique for labor analgesia, but can be associated with slow onset and inadequate sacral spread, unilateral or patchy sensory blockade, motor impairment. The combined spinal epidural (CSE) technique can provide rapid onset of analgesia, but is associated with greater side effects, including pruritus, fetal bradycardia and delayed testing of epidural catheters. Dural puncture epidural (DPE) technique is a modification of CSE technique. A spinal needle is introduced through the epidural needle to create a single dural puncture , after intrathecal space was identified by the free flow of cerebrospinal fluid (CSF) , the needle was removed without direct medication administration into the subarachnoid space. Privous studies have demonstrated that the DPE technique can improve block quality over the EPL technique with fewer maternal and fetal side effects than the CSE technique for parturients requesting labor analgesia. Besides the neuraxial techniques, maintenance regimens is another factor that affect the analgesic effect. Programmed intermittent epidural bolus (PIEB) provides greater spread of local anesthetic solution within the epidural space and therefore superior quality of analgesia compared with continuous epidural infusion (CEI). We designed this prospective randomized, double-blind study to evaluate the safety and efficacy of the combined implementation of DPE technique and PIEB for labor analgesia.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | EPL and CEI | Procedure: Standard epidural placement(EPL) Drug: ropivacaine Drug: sufentani 0.1% ropivacaine + sufentanil 0.3μg/mL Device: Infusion pump Infusion pump set to continuous epidural infusion(CEI) plus patient-controlled epidural analgesia (PCEA). |
| OTHER | DPE and CEI | Procedure: Dural puncture epidural (DPE) Epidural with spinal needle placed to create a single dural puncture and confirm free flow of cerebral spinal fluid (CSF) , without direct medication administration into the subarachnoid space. Drug: ropivacaine Drug: sufentani 0.1% ropivacaine + sufentanil 0.3μg/mL Device: Infusion pump Infusion pump set to continuous epidural infusion(CEI) plus patient-controlled epidural analgesia (PCEA). |
| OTHER | DPE and PIEB | Procedure: Dural puncture epidural (DPE) Epidural with spinal needle placed to create a single dural puncture and confirm free flow of cerebral spinal fluid (CSF) , without direct medication administration into the subarachnoid space. Drug: ropivacaine Drug: sufentani 0.1% ropivacaine + sufentanil 0.3μg/mL Device: Infusion pump Infusion pump set to programmed intermittent epidural boluses (PIEB) plus patient-controlled epidural analgesia (PCEA). |
Timeline
- Start date
- 2017-10-10
- Primary completion
- 2018-06-08
- Completion
- 2018-06-30
- First posted
- 2017-12-08
- Last updated
- 2018-08-01
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT03366935. Inclusion in this directory is not an endorsement.