Application of speCtraL Computed tomogrAphy to impRove specIficity of Cardiac compuTed tomographY

Diagnostic Accuracy of Spectral Computed Tomography for Detection of Flow Limiting Coronary Stenosis Using Fractional Flow Reserve as the Standard of Reference

Status
Unknown
Phase
Study type
Observational
Enrollment
75 (estimated)
Sponsor
UMC Utrecht · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Cardiovascular disease remains the leading cause of morbidity and mortality worldwide. Coronary computed tomography angiography (CCTA) and, if indicated, invasively measured fractional flow reserve (FFR) is currently used for ruling out significant coronary artery disease. FFRCT is a novel non-invasive technique in which FFR is derived from CT images, however this method is currently, just like CCTA, lacking specificity. Spectral Detector CT (SDCT) is a novel technique whereby a spectrum of monoenergetic images at different kiloelectron Volt (keV) values (40 to 200 keV) can be reconstructed. By using these monoenergetic images, a decrease in blooming and beam-hardening artifacts could be achieved. In addition, SDCT offers the opportunity to assess myocardial iodine distribution and quantification. When combining these factors, we hypothesize more accurate information will be available about the coronary anatomy, degree of stenosis and FFRCT and thereby contribute to a more accurate way for the detection of hemodynamic significant stenosis. Therefore, the aim of this study is to assess the accuracy of SDCT as a non-invasive way for the detection of hemodynamically significant coronary artery stenosis. Objective: The overall objective of this project is to assess the accuracy of SDCT for the detection of flow limiting stenosis in the coronary arteries using invasive FFR as the standard of reference. Whereby different sub-aims (e.g. improvement of FFRCT) are made to answer the overall objective. The secondary objective is to determine the decrease of calcium blooming of calcifications and beam-hardening artifacts and the improvement of myocardial blood volume quantification on SDCT in comparison with conventional CT.

Conditions

Interventions

TypeNameDescription
DEVICEDual-layer spectral detector CTA dual energy CT approach

Timeline

Start date
2017-03-29
Primary completion
2021-03-29
Completion
2021-09-01
First posted
2017-05-03
Last updated
2018-10-17

Locations

1 site across 1 country: Netherlands

Regulatory

Source: ClinicalTrials.gov record NCT03139006. Inclusion in this directory is not an endorsement.

Application of speCtraL Computed tomogrAphy to impRove specIficity of Cardiac compuTed tomographY (NCT03139006) · Clinical Trials Directory