Clinical Trials Directory

Trials / Completed

CompletedNCT03094390

Thoracic Fluid Content in Prediction of Failure of Weaning From Mechanical Ventilation

The Impact of Thoracic Fluid Content Measured by Cardiometry on Prediction of Failure of Weaning From Mechanical Ventilation

Status
Completed
Phase
Study type
Observational
Enrollment
64 (actual)
Sponsor
Cairo University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This study aims to test the accuracy of the total thoracic fluid content (TFC) measured by cardiometry can predict weaning failure. Area under receiver operating characteristic curve (AUROC) will be determined, sensitivity, specificity, and best cutoff value will be calculated for TFC in prediction of weaning failure.

Detailed description

Weaning from mechanical ventilation is a serious and challenging process in critical care practice. Weaning failure is associated with poor patient outcomes. Increased mortality in patients with failed weaning was due to development of complications related to re-intubation. Detection and correction of the cause of failed spontaneous breathing trial (SBT) helps the intensives to improve the outcome of the next trials. Fluid overload and positive cumulative fluid balance is a risk factor of weaning failure in both cardiac and non-cardiac patients. Many tools for prediction of lung congestion as a risk factor for weaning failure have been reported. The gold standard for detection of cardiac cause of weaning failure was pulmonary artery catheter. More simple tools had been investigated for detection of cardiac cause of weaning failure in patients with or without previous cardiac dysfunction such as extravascular lung water and B-natriuretic peptide (BNP) levels. Although measurement of extravascular lung water is a reliable tool for prediction of cardiac cause of weaning failure, it has the disadvantage of the need of advanced monitor with invasive arterial line. Bioreactance is a new technology used for measurement of cardiac output and total thoracic fluid content (TFC). More recently, electrical velocimetry is a newer technology with good performance in cardiac output monitoring. The use of electrical velocimetry in measurement of TFC has the advantage of being non-invasive with no need for advanced skills. The aim of this work is to validate the use of TFC (measured by electrical velocimetry) in prediction of weaning outcome.

Conditions

Timeline

Start date
2017-04-04
Primary completion
2018-09-01
Completion
2018-09-10
First posted
2017-03-29
Last updated
2019-06-13

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT03094390. Inclusion in this directory is not an endorsement.