Trials / Completed
CompletedNCT03014232
Comparison Cytokine Clearance Between SLED-f Using High Cut-off Dialyzer and High-flux Dialyzer in Septic AKI Patients
Comparison Cytokine Clearance Between Sustained Low-Efficiency Diafiltration (SLED-f) Using High Cut-off Dialyzer and High-flux Dialyzer in Septic AKI Patients
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 16 (actual)
- Sponsor
- Chulalongkorn University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Hypercytokinemia contributes a major role in the pathogenesis and is associated with the high mortality in sepsis-related acute kidney injury(AKI). This pilot randomized controlled trial was conducted in sepsis-related AKI patients to compare the efficacy of cytokine removal including interleukin(IL)-6, IL-8, IL-10, and tumor necrotic factor(TNF)-α by six-hour SLED-f between using HCO dialyzer(HCO-SLED-f) and HF dialyzer(HF-SLED-f).
Detailed description
Hypercytokinemia contributes a major role in the pathogenesis and is associated with the high mortality in sepsis-related acute kidney injury(AKI). Reductions of these cytokines have been reported to improve clinical outcomes. Online sustained low-efficiency diafiltration(SLED-f) using traditional high-flux(HF) dialyzer could remove some cytokines. Interestingly, the potential of enhancing cytokine removal by using newly designed high cut-off(HCO) dialyzer that could theoretically remove larger molecular weight solutes has never been studied in SLED-f before.This pilot randomized controlled trial was conducted in sepsis-related AKI patients to compare the efficacy of cytokine removal including interleukin(IL)-6, IL-8, IL-10, and tumor necrotic factor(TNF)-α by six-hour SLED-f between using HCO dialyzer(HCO-SLED-f,n=8) and HF dialyzer(HF-SLED-f,n=8).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | SLED-f with HCO dialyzer | Online SLED-f with high cut-off dialyzers were performed using the Fresenius 5008S hemodiafiltration machines (Fresenius Medical Care, Bad Homburg, Germany). Super-flux, Sureflux 150FH (Nipro Corporation, Osaka, Japan; cellulose triacetate material, pore size 78 A◦, Kuf 66.9 mL/hr/mmHg, surface area 1.5 m2) were used. Dialysis time and blood flow rate were 6 hours and 200 mL/min, respectively. The predilution reinfusion fluid rate and dialysate flow rate were 80 and 220 mL/min, respectively (the total dialysis fluid flow rate was 300 mL/min). |
| PROCEDURE | SLED-f with HF dialyzer | Online SLED-f with standard high-flux dialyzers were performed using the same Fresenius 5008S hemodiafiltration machines (Fresenius Medical Care, Bad Homburg, Germany). High-flux ELISIO 150H (Nipro Corporation, Osaka, Japan; polynephron material, pore size 50-60 A◦, Kuf 67 mL/hr/mmHg, surface area 1.5 m2) were used. Dialysis time and blood flow rate were 6 hours and 200 mL/min, respectively. The predilution reinfusion fluid rate and dialysate flow rate were 80 and 220 mL/min, respectively (the total dialysis fluid flow rate was 300 mL/min). |
Timeline
- Start date
- 2012-06-01
- Primary completion
- 2013-06-01
- Completion
- 2013-06-01
- First posted
- 2017-01-09
- Last updated
- 2017-01-09
Source: ClinicalTrials.gov record NCT03014232. Inclusion in this directory is not an endorsement.