This study compared the anesthetic efficacy between Lignocaine and articaine administering it intraligamentarly using ligajet in twenty five female patients having irreversible pulpitis on bilateral mandibular molars. At 5minutes of post injection, the teeth were isolated with rubber dam and access performed. Patients were instructed to definitively rate any pain felt during endodontic procedure. If patient felt pain, the treatment was immediately stopped and the patient rated their discomfort using Heft Parker VAS. The extent of access achieved when the patient felt pain was recorded as within dentin, entering the pulp chamber or initial file placement. The success was defined as the ability to access and instrument the tooth without pain (VAS score of zero) or mild pain (VAS rating\<54mm).

Detailed description

The present clinical study was carried out to compare the anaesthetic success of 4% articaine with 2% lidocaine for intraligamentary anaesthesia in patients having irreversible pulpitis. Subjects randomly received two intraligamentary injections using Ligaject at a two separate appointments spared one week apart in a cross over design. Twenty patients received intraligamentary injections of 0.9 ml of 4%articaine with 1:100,000 epinephrine (Septodont INC) at first appointment and 1.8 ml of lidocaine with 1:100,000 epinephrine. Each patient served as her own control. All injections were given by the same physician or author. The injection was performed by inserting the needle at the gingival sulcus at the mesio-buccal line angle of the tooth with needle directed at approximately 30degrees angle to the long axis of the tooth in the buccolingual plane. Needle was placed into the sulcus with the bevel placing away from the tooth and towards the alveolar bone. Needle was advanced with a firm pressure until it could be advanced no further. The operator waited 10 seconds before slowly removing the needle from the injection site. This step supposedly allows the anaesthetic solution to dissipate within the tissue and reduces the amount of anaesthetic solution to dissipate within the tissue and reduces the amount of solution dripping from the site before needle withdrawal. However, in almost all cases some anaesthetic solution escaped upon removal of needle from the sulcus. Five minutes post injection, the teeth were isolated under rubber dam isolation and investigator performed the access cavity. Patients were instructed to definitely rate any pain felt during endodontic procedure. If patient felt pain, the treatment was immediately stopped and the patient rated her discomfort using Heft Parker VAS. The extent of access achieved when the patient felt pain was recorded as within dentin, entering the pulp chamber or initial file placement. The success was defined as the ability to access and instrument the tooth without pain (VAS score of zero) or mild pain (VAS rating\<54mm).

Conditions

Interventions

TypeNameDescription
DRUG4%articaineintraligamentary injections of 0.9 ml of 4%articaine and 1:100,000 epinephrine
DRUG2% LignocaineIntraligamentary injections of 1.8 ml of lidocaine and 1:100,000 epinephrine
DRUGEpinephrineIntraligamentary injections of 1.8 ml of lidocaine and 1:100,000 epinephrine