Clinical Trials Directory

Trials / Completed

CompletedNCT02587832

High Flow Nasal Cannula in Comparison With Nasal Continuous Positive Airway Pressure in the Management of Respiratory Distress Syndrome

Randomized Control Trial: Heated Humidity High Flow Nasal Cannula in Comparison With Nasal Continuous Positive Airway Pressure in the Management of Respiratory Distress Syndrome in Extreme Low Birth Infants in Immediate Post Extubation Period

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
60 (actual)
Sponsor
Sidra Medicine · Academic / Other
Sex
All
Age
Healthy volunteers
Not accepted

Summary

To compare the primary outcome, failure of extubation defined by the need for re-intubation and mechanical ventilation within 5 days of initial extubation and secondary outcomes, morbidities and mortality after using of heated humidity high flow nasal cannula (HHHFNC) and Nasal Continuous Positive Airway Pressure (NCPAP) in the immediate post-extubation period for preterm infants between 24 and 28 weeks gestation with respiratory distress syndrome.

Detailed description

Inclusion criteria were: 1) Preterm neonates with gestational age of 24 to 28 completed weeks. 2) In the case of twins, both neonates were included in the same treatment arm. 3) Success to wean with 24 hours to extubate. 4) Parental written informed consent for participation in the study obtained on admission into the hospital or prior to delivery. Exclusion criteria were: 1) Evidence of severe birth asphyxia. 2) Known genetic or chromosomal disorders. 3) Infants delivered to mothers with ruptured membranes of more than three weeks duration. 4) Potentially life-threatening conditions unrelated to prematurity. 5) Participation in another clinical trial of any placebo, drug, biological, or device conducted under the provisions of a protocol. Randomization A computer-generated block-randomization sequence with random block sizes was used. Infants who were part of multiple births underwent individual randomization. Clinicians opened consecutively numbered, sealed, brown envelopes immediately before extubation to determine the study-group assignment.

Conditions

Interventions

TypeNameDescription
DEVICEHHHFNCTri-Anim Vaptherm the Precision Flow, which is a self contained unit that provides flow rates up to or 8 LPM (Infants) of blended oxygen that is heated and humidified
DEVICENCPAPBubble CPAP System.

Timeline

Start date
2009-07-01
Primary completion
2012-04-01
Completion
2012-04-01
First posted
2015-10-27
Last updated
2015-10-27

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT02587832. Inclusion in this directory is not an endorsement.