Clinical Trials Directory

Trials / Recruiting

RecruitingNCT02420470

The Early Warning System for the Diabetic Encephalopathy

The Early Warning System for the Central Nervous System Micro-structure Alterations During Early Diabetes Based on the Multi-mode MRIs

Status
Recruiting
Phase
Study type
Observational
Enrollment
300 (estimated)
Sponsor
Tang-Du Hospital · Academic / Other
Sex
All
Age
40 Years – 65 Years
Healthy volunteers
Accepted

Summary

Diabetes( mainly type II diabetes )lead to the central nervous system (CNS) function impairment, especially the mild cognitive impairment that increased the risk of progression to dementia.The primary objectives are defined according to a hierarchical design: i) to tailor and apply multi-parametric, functional MRI techniques to identify cerebral abnormalities (cerebral biomarkers) in type 2 diabetes mellitus and prodromal diabetes mellitus ; ii) to assess whether these cerebral biomarkers are associated with cognitive decrements;iii) to follow up with the putative prediabetic condition patients to verify whether they can transform into diabetes.

Detailed description

Diabetes ( mainly type II diabetes ) lead to the central nervous system (CNS) function impairment, especially the mild cognitive impairment (MCI) that increased the risk of progression to dementia. It was regarded that neurodegeneration contributes to the diabetic MCI, however, recent research suggested that CNS microvascular alterations are the mechanism for early diabetic MCI. But there still lacks an early warning system for the CNS micro-structure alterations during early diabetes. Latest neuroimaging techniques enable the measurement of brain blood flow, local neural activity,and the nuclei deposition of iron to reflect CNS micro-structure alterations. But these techniques are complicated and can not fully reflect the alterations with one single technique.We previous observed that 44.4% of diabetic patients demonstrate MCI and established the comprehensive protocols of measuring brain blood flow, local neural activity and the nuclei deposition of iron simultaneously based on the multimodal MRI technique so as to reflect the microstructure alterations reliably and validly. Therefore, we intend to integrate psychological measurement and clinical biochemical examination, and to establish the early warning system for the central nervous system micro-structure alterations during early diabetes based on the multi-modal MRI technique. The reliability and validity of this system will be tested in the diabetic rat model. The early warning system will likely assist in screening patients with diabetic microstructure alterations, to perform early intervention so as to prevent or delay the progression from diabetic MCI to dementia.

Conditions

Timeline

Start date
2015-04-01
Primary completion
2025-11-01
Completion
2026-12-01
First posted
2015-04-17
Last updated
2022-07-13

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT02420470. Inclusion in this directory is not an endorsement.

The Early Warning System for the Diabetic Encephalopathy (NCT02420470) · Clinical Trials Directory