Clinical Trials Directory

Trials / Completed

CompletedNCT02297334

Removal of Cytokines During Extracorporeal Circulation in Cardiac Surgery

Reduction of Inflammation Reaction to Extracorporeal Circulation in Cardiac Surgery by Interleukin Dialysis

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
40 (actual)
Sponsor
Universitätsklinikum Hamburg-Eppendorf · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The aim of this study is to prove that using a CytoSorb(TM) filter in the cardiopulmonary circuit attenuates the inflammatory response to extracorporeal circulation in patients undergoing cardiac surgery. The hypothesis is that removing cytokines from patients' blood by the CytoSorb device significantly improves circulation and outcome in patients undergoing on-pump cardiac surgery.

Detailed description

Cardiac surgery with cardiopulmonary bypass (CPB) induces an inflammatory response due to contact of patients' blood with foreign surfaces like tubes or the oxygenator, ischemic-reperfusion injury and surgical trauma. Inflammation is modulated by cytokines, especially, interleukins. The extent of cytokine release is further related to the duration of bypass and the amount of operating field suction. This results in a systemic inflammatory response syndrome (SIRS) with the risk of multiple organ dysfunction (MOD). Also in patients treated with extracorporeal membrane oxygenation (ECMO) an activation of the inflammation system is seen and accompanied with an increase of cytokine levels. The cytokine concentration correlates with the severity of the immune reaction and can be a predictor of the outcome of the patient. As severe SIRS and MOD significantly increase mortality, the attenuation of the inflammatory response is supposed to reduce morbidity and mortality after cardiac surgery. For adult cardiac surgery and patients who are treated with an extracorporal assist device, a tool for cytokine elimination and attenuation of the inflammatory response seems to be beneficial. In our study we are going to investigate if the use of the CytoSorb device can improve the outcome of patients undergoing elective coronar artery bypass and heart valve surgery.

Conditions

Interventions

TypeNameDescription
DEVICECytoSorb deviceIn 20 patients the CytoSorb device will be installed into the extra corporeal circuit. A blood flow of 400ml/min is provided by an roller pump of the heart lung machine in a parallel stream to the main circulation.

Timeline

Start date
2013-09-01
Primary completion
2015-10-01
Completion
2017-08-01
First posted
2014-11-21
Last updated
2017-08-29

Locations

1 site across 1 country: Germany

Source: ClinicalTrials.gov record NCT02297334. Inclusion in this directory is not an endorsement.