Clinical Trials Directory

Trials / Completed

CompletedNCT02286063

Ambulatory Oxygen in Fibrotic Lung Disease (FLD) (AmbOx)

Randomized, Controlled Crossover Trial to Evaluate the Effects of Ambulatory Oxygen on Health Status in Patients With Fibrotic Lung Disease (FLD).

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
70 (actual)
Sponsor
Royal Brompton & Harefield NHS Foundation Trust · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The main aim of this project is to establish whether ambulatory oxygen in patients with fibrotic ILD whose oxygen saturation falls ≤ 88% on a 6MWT, leads to a significant improvement in health status. The core of the project will be a four week randomised, crossover controlled trial of ambulatory oxygen used during daily activities. The optimal Oxygen flow rate is determined by titration at screening visit and administered during activity for a two-week period, compared to two weeks off oxygen.

Detailed description

The planned non-commercial study is a randomised, controlled crossover trial of ambulatory oxygen against no ambulatory oxygen over a four week period (two weeks on ambulatory oxygen and two weeks on air, with no portable devices), to evaluate the effects of ambulatory oxygen on health status in patients with ILD. A short crossover study in this context has many advantages, since ambulatory oxygen has immediate effect, with no wash-out period needed after use. The primary outcome of the study will be the change in health status, as measured by the K-BILD questionnaire (Thorax 2012 67: 804-810). At the start of the trial, the effects of ambulatory oxygen on 6 Minute Walk Test (6MWT) parameters will be evaluated on oxygen and on air-filled canisters, with the patient blind to the contents of the canister, to assess whether oxygen-induced improvements in 6MWT parameters can predict its effectiveness in day to day life. The 6MWT is a well established and highly reproducible test validated in ILD patients, with significant prognostic implications. The study design does not include a placebo arm because: 1. The intervention is a combination of possible benefits from oxygen and the disadvantage of canister weight. These cannot be separated. Placebo control is impossible because there is no means of providing placebo weight. Attempts to control solely for oxygen use without taking canister weight into account are clinically meaningless. In a recent COPD, chronic obstructive pulmonary disease study, cylinder weight was reported as a barrier to use by 93% of study participants. 2. A positive result against an air-filled canister arm would be clinically uninterpretable. This is a study design in which the 'placebo' would be actively harmful to study participants. Carriage of an air-filled cylinder would be expected to lead to earlier desaturation and reduced exercise tolerance. Such a design would not inform the real life comparison between oxygen plus cylinder and no intervention. 3. All this aside, blinding is legally impossible (UK health and safety regulations require that oxygen cylinders for home use must be clearly labelled). It should also be stressed that objective measures of change are evaluated as secondary end-points: the investigators expect to explore correlations between these variables and the primary end-point to exclude the possibility that an observed treatment benefit on the primary end-point might be confounded by a placebo effect. A more in depth qualitative assessment of the impact of ambulatory oxygen will be undertaken via a semi-structured interview, in a subset of 20 patients, to investigate patients' and their carers' personal perspective on how the ambulatory oxygen has affected their day to day life. The interview will be conducted within 2 weeks of the end of treatment visit. Patients from the Royal Brompton Hospital site will be approached by the researcher at the end of treatment visit and asked if they will participate in the qualitative assessment. If the patient agrees a date will be agreed for the patient to be interviewed at a venue convenient to them (usually the patient's home). During the interviews a semi-structured topic guide will address practical barriers to optimal oxygen usage, practical, social and psychological difficulties encountered, concerned about dependency, and views on the information required prior to ambulatory oxygen prescription. The interviews will also explore patients' (and carers') experience of participating in the trial. Notes will be written after each interview to aid reflective analytical processes. Individual feed back on how the system and the service could be improved will assess how the needs of patients and their future involvement can be incorporated into the design of more patients and their future involvement can be incorporated into the design of more patients centred devices. Qualitative interview analysis: Interviews will be transcribed verbatim. Interview transcripts will be analysed thematically using a framework approach. Atlas/ti computer software (http://atlasti.com) will be used to manage and index the data prior to charting, mapping and interpretation.

Conditions

Interventions

TypeNameDescription
DRUGAmbulatory OxygenThe IMP investigated in this study is medical oxygen (PL 15929/005), manufactured by Air Liquide Ltd. UK. Oxygen is a colourless, odourless gas with molecular weight 32, a boiling point of 183.1°C (at 1 bar) and a density of 1.355 kg/m3 (at 15°C and 1013mb). Oxygen is present in the atmosphere at 21% and is an absolute necessity for life. Each of the four oxygen companies across the UK provide a light and a standard weight oxygen cylinder. Ambulatory Oxygen will be given to the Oxygen arm.

Timeline

Start date
2014-08-01
Primary completion
2018-01-31
Completion
2018-01-31
First posted
2014-11-07
Last updated
2018-06-26

Locations

1 site across 1 country: United Kingdom

Source: ClinicalTrials.gov record NCT02286063. Inclusion in this directory is not an endorsement.