Clinical Trials Directory

Trials / Completed

CompletedNCT02236559

High Flow Therapy for the Treatment of Respiratory Failure in the ED

Vapotherm High Flow Therapy for the Treatment of Respiratory Failure in the ED: A Randomized Controlled Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
204 (actual)
Sponsor
Vapotherm, Inc. · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The overall objective of this study is to determine if Vapotherm high flow nasal cannula therapy (HFT), when used to treat respiratory failure in the ED, is at least equivalent to the current standard of care for non-invasive ventilatory support, non-invasive positive pressure mask ventilation (NIPPV). Moreover, this study will investigate the potential that HFT has possible advantages over NIPPV, such as decreased time to patient stability from respiratory failure, and the ease of use as a first line intervention for respiratory failure in the ED environment. The hypothesis is that HFT via the Vapotherm Precision Flow will demonstrate clinical non-inferiority when compared to NIPPV with regard to treatment failure by way of an impact on ventilation indices and a lower intolerance rate, and have a positive association with hospital disposition and length of stay.

Conditions

Interventions

TypeNameDescription
DEVICENoninvasive positive pressure ventilation (NIPPV)Patients will be fit with an oronasal mask using a fitting gauge that will be applied by a respiratory therapist or other clinician skilled in management of NIPPV. Initial pressures will be at low end of suggested range but can be increased as rapidly as necessary to alleviate respiratory distress. Targets should be to lower respiratory rate to the low 20s and achieve tidal volumes of 6-8 ml/kg ideal body weight. If patients find pressures uncomfortably high, they can be lowered as necessary by 1 to 2 cmH2O decrements to enhance tolerance. EPAP (PEEP) can also be adjusted upward as needed to reduce triggering effort (by counterbalancing auto-PEEP) or to improve oxygenation. FIO2 will be 1.0 initially to assure adequate oxygenation, but should be adjusted promptly to maintain an FIO2 of no greater than 0.6 with an EPAP (PEEP) of not more than 10 cm H2O to maintain a PaO2 \> 88%.
DEVICEVapothermPatients will be fit with a Vapotherm adult nasal cannula that will be applied by a respiratory therapist or other clinician skilled in management of HFT. Initial flow will be set to 35 L/min but can be decreased or increased as rapidly as necessary to alleviate respiratory distress and optimize patient comfort. Targets should be to lower respiratory rate to the low 20s and with a HFT flow rate between 20 to 35 L/min. Starting temperature will be between 35 to 37 C; if patients find the gas temperature to be uncomfortable, it can be lowered as necessary down to 33 C to enhance tolerance. FIO2 will be 1.0 initially to assure adequate oxygenation, but should be adjusted promptly to maintain an FIO2 of no greater than 0.6 to maintain a PaO2 \> 88%.

Timeline

Start date
2014-09-01
Primary completion
2016-09-01
Completion
2017-02-01
First posted
2014-09-10
Last updated
2019-05-23
Results posted
2019-05-23

Locations

5 sites across 1 country: United States

Source: ClinicalTrials.gov record NCT02236559. Inclusion in this directory is not an endorsement.