Clinical Trials Directory

Trials / Completed

CompletedNCT01849822

Providing Brain Control of Extracorporeal Devices to Patients With Quadriplegia

A Feasibility Study of the Ability of the Neural Prosthetic System to Provide Direct Brain Control of Extracorporeal Devices in Patients With Quadriplegia Due to High Spinal Cord Injury

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
1 (actual)
Sponsor
Richard A. Andersen, PhD · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

This research study is being done to develop a brain controlled medical device, called a brain-machine interface or BMI, that will provide people with a spinal cord injury some ability to control an external device such as a computer cursor or robotic limb by using their thoughts. Developing a brain-machine interface (BMI) is very difficult and currently only limited technology exists in this area of neuroscience. The device in this study involves implanting very fine recording electrodes into areas of the brain that are known to create arm movement plans and provide hand grasping information. These movement and grasp plans would then normally be sent to other regions of the brain to execute the actual movements. By tying into those pathways and sending the movement plan signals to a computer instead, the investigators can translate the movement plans into actual movements by a computer cursor or robotic limb. The device being used in this study is called the NeuroPort Array and is surgically implanted in the brain. This device and the implantation procedure are experimental which means that it has not been approved by the Food and Drug Administration (FDA). One NeuroPort Array consists of a small grid of electrodes that will be implanted in brain tissue with a small cable that runs from the electrode grid to a small hourglass-shaped pedestal. This pedestal is designed to be attached to the skull and protrude though the scalp to allow for connection with the computer equipment. The investigators hope to learn how safe and effective the NeuroPort Array is in controlling computer generated images and real world objects, such as a robotic arm, using imagined movements of the arms and hands. To accomplish this goal, two NeuroPort Arrays will be used.

Conditions

Interventions

TypeNameDescription
DEVICENeural Prosthetic SystemThe Neural Prosthetic System is primarily composed of two NeuroPort Arrays. Each array is comprised of 100 microelectrodes (1.5 mm in length) uniformly organized on a 4 mm x 4 mm silicon base that is 0.25 mm thick. Each microelectrode is insulated with Parylene-C polymer and is electrically isolated from neighboring electrodes by non-conducting glass. Each microelectrode has a platinum tip that is 100-200 microns in length and offers impedance values from 100-800 kilo-ohms. Of the 100 electrodes, 96 are wire bonded using 25 micron gold alloy insulated wires collectively sealed with a silicone elastomer. The wire bundle is potted to a printed circuit board with epoxy, the printed circuit board is inserted into the Patient Pedestal (percutaneous connector), and then the Patient Pedestal is filled with silicone elastomer. Two fine platinum reference wires are also attached to the Patient Pedestal. The Patient Pedestal is 19 mm wide at the skin interface.

Timeline

Start date
2013-02-01
Primary completion
2019-01-01
Completion
2019-01-01
First posted
2013-05-09
Last updated
2021-04-30
Results posted
2021-04-30

Locations

3 sites across 1 country: United States

Source: ClinicalTrials.gov record NCT01849822. Inclusion in this directory is not an endorsement.